Alex W.

Alex W.


Job Checkin

I removed all the bathroom outlets and replaced them with tamper resistant GFCIs. I removed all outdoor outlets and replaced them with weather resistant tamper resistant GFCIs with in use bubble covers I also fixed all the issues in the receptacles the previous owner did when wiring the outlets including removed a open ring and installed a old work box to protect the device and wiring I spliced all appropriate wires together and pig tailed off the spliced to the receptacles I line sided all the devices so if one were to trip it will not affect the rest of the devices in the bathrooms or outside Previous owner had a open air splice outside under the deck and used romex which isn’t rated for outside so I dug the ground and found the uf cable then used a under ground splice kit then piped pvc over with uf cable in it under ground then up under the deck. I removed the box because it wasn’t rated to be outside so I used a weather proof connector into a weather proof box and wired a