Alex W.

Alex W.


Job Checkin

Customer had a existing range circuit that was a 6-2 aluminum wire and they got a new range that required a 6-3. So I ran a 6-3 romex wire from the main electrical panel in the side bedroom up into the attic and through the attic down into the kitchen. I installed a flush mount 4 prong 50 amp receptacle and a square d QO 50 amp 2 pole breaker after terminating the existing range circuit. Customer was informed about having to cut holes above panel and we do not patch the drywall I left a few feet of slack in the attic per customers request because one day they may remodel the kitchen and if they needed to relocate the plug they were able too. I supported the wire in the attic and tested everything Customer has a 1 year warranty