Nicholas T.

Nicholas T.


Job Checkin

Reason for todays visit was to replace an exterior receptacle that wasn’t working properly. While assessing issue we found that the kitchen GFCI to the right of the sink was controlling the rear receptacle that had the issue. The GFCI is 32 years old (original) and seams to be tripping to often. Re replaced the rear receptacle with a new weather resistant device and replaced the GFCI controlling it. We also put silicone around the cover to keep water from running inside. We also added a new GFCI next to the meter on its own 20 amp circuit. We installed a new weather resistant device and a new in-use cover to protect device. We tested all 3 devices and they are functioning properly. The GFCI’s will still trip if water gets into any cord connection plugged in these devices. There is many Christmas lights and cords laying on the ground unprotected in the yard. While in the panel we noticed that there was no surge protection present. Panel looks as though it is all original to the 1990 bu