9800 Old Dogwood Rd.
Roswell, GA 30075
(770) 667-6937

Our Top Cities


Job Locations
for jasper, ga


Map of Jasper GA
James D.

James D.


Job Checkin

I came out today due to the homeowner requesting to have new location receptacles installed for some toilets. Due to the second floor installing a new dedicated circuit is not feasible without causing significant damage to the home. The electrical specifications calls for a dedicated 15 amp circuit at 1800 W. I informed the customer that the toilet will still work but she runs the risk of potentially tripping the circuit breaker. If she runs the heater at max she let me know today that she doesn’t plan on using the toilet seat heater at all And she understands the potential of the breaker tripping due to overload conditions. I came off a receptacle in the master bedroom adjacent from the powder, bathroom wall and completed a back to back installation by the toilet. I supplied and installed a GFCI receptacle in the master bedroom to provide proper shock prevention next to the toilet. I showed the homeowner where the GFI was, explained the red light, and how to reset it during the even