Portable Extinguishers and Emergency / Exit Lights Inspection FP Annual - Qty 4 FP Annual
Did not test door, recommend replacing.
FP Semi-Annual Kitchen Suppression Inspection
Alarm Systems Inspection FP Annual
Kitchen Suppression and Portable Extinguishers Inspection FP Semi-Annual FP Annual
Kitchen Suppression and Portable Extinguishers Inspection FP Semi-Annual FP Annual
Buckeye BF 20,15: FP Semi Annual Kitchen Suppression Inspection
FP Semi-Annual FP Annual FP Annual Inoperable Deficiency: Red tag system needs maintenance. Repipe of appliances for new restaurant with existing suppression system. Detection line and black pipe need extended to additional hood. QSAs needed(see video) 4 burner range: 24x24in 4 total fryers: 15x14x7in drip board Duct:12x12in Gas valve already installed Pull station already installed. Protex 2 tank needs increased to combat flows. L3000 in use already. REPAIR TRUCK NEEDED! System left disarmed Kitchen Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection
TN 319744046 Portable Extinguishers Service Call Service call for extinguisher at pump 15/16 needs recharged.
TN 318273948 Kitchen Suppression Inspection Ansul Ansul r102 6: FP Semi Annual - Ansul
Portable Extinguishers and Kitchen Suppression Inspection FP Annual Ansul R102 6: FP Semi Annual Suggested: Blocked fire extinguisher
TN 318273919 Kitchen Suppression Inspection FP Semi Annual - Ansul Frequency: Jan/Jul
Emergency / Exit Lights, Portable Extinguishers, and Kitchen Suppression Inspection FP Annual FP Annual FP Semi Annual
Portable Extinguishers and Emergency / Exit Lights Inspection FP Annual FP Annual
FP Semi Annual Inoperable Deficiency: Ansul 4.5g system is red tagged. 12 year maintenance needed. 2010 date of manufacturer not manifolded. 101-30 cartridge. 2 total hoses. Detection line needs replaced. 4 total Ansul link detectors. Line is clogged heavily with grease and won’t trip system. No fire alarm tied in. Repipe of appliances needed. 6 burner range needs 3-1F nozzles. Single burner needs 1N nozzle Kitchen Suppression Inspection