Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 13492777 - Duct nozzle extends more than 6" into the duct and will require adjustment to meet manufacturer listing - Holes in duct left by the damper that was removed need to be sealed to meet compliance Repair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Fire Suppression Repair Ansul R102 3g Broiler hood: Kitchen System Broiler: Duct nozzle is greater than 6" into the duct. This is not allowed by the manufacturer. Both the duct and plenum penetration lack proper quick seal devices. Their are holes on either side of the duct from a damper that has been removed those holes require a quick seal patch. - repair Deficien
Portable Extinguishers and Fire Suppression Inspection FIRE EXTINGUISHERS - QTY UNKNOWN FX TO BE DONE WITH KS KITCHEN SYSTEM - ZONE 3 ANSUL 4.5 GALLON, RED BD - FRY HOOD HYDRO: (2) 2008 ANSUL 3.0 GALLON, RED BD - BROILER HOOD HYDRO: 2008 KS TO BE DONE WITH FX & EL Deficiency: Both Systems are non compliant due to system cylinders are the red type. These cylinders need to be swapped out for silver tanks. Red tanks starting to corrode. Also customer has either a roof leak or the hood cleaning company left a lot of water on top of the broiler hood. Water was leaking through the penetration seal for the broiler appliance. This seal will need to be changed when we return with the new cylinders. Cylinders need are 2x 3g and 1x 1.5g ansul
Fire Suppression Inspection Kitchen System - Zone 3 Ansul 4.5 G Red w/BD - fryer hood Hydro: (2) 2008 R102 3.0 G Red - broiler hood Hydro: 2008 KS TO BE DONE WITH FX & EL
Fire Suppression Inspection KITCHEN SYSTEM - ZONE 3 PROTEX L 4600 HYDRO: 2014 KS TO BE DONE WITH FX
Portable Extinguishers, Emergency / Exit Lights, and Fire Suppression Inspection FIRE EXTINGUISHERS - QTY UNKNOWN FX TO BE DONE WITH KS EMERGENCY LIGHT - KS TO BE DONE WITH EL 2 Kitchen Systems - Zone 3 Ansul 3.0 G Red - Broiler Hood Hydro: 2008 Ansul 6.0 G Red/SSBD - Fryer Hood Hydro: 2008 new KS TO BE DONE WITH FX & EL
Emergency / Exit Lights, Portable Extinguishers, and Fire Suppression Inspection EMERGENCY LIGHT - KS TO BE DONE WITH EL FIRE EXTINGUISHERS - QTY UNKNOWN FX TO BE DONE WITH KS Kitchen System - Zone 3 Ansul 4.5 G Red w/BD - fryer hood Hydro: (2) 2008 R102 3.0 G Red - broiler hood Hydro: 2008 KS TO BE DONE WITH FX & EL
Portable Extinguishers and Fire Suppression Inspection FIRE EXTINGUISHERS - QTY 3 FX TO BE DONE WITH KS KITCHEN SYSTEM - ZONE 3 PROTEX L 4600 HYDRO: 2014 KS TO BE DONE WITH FX