Fire Suppression Inspection KITCHEN SYSTEM - QTY 1 PCL-460 - HYDRO 2017 KS ALL INCLUSIVE KS TO DO FX @ SAME TIME


Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Inspection Semiannual Kitchen Fire Suppression System Inspection - QTY 2 Main Hood - PCL-460 - HYDRO 2011 Small Hood - KP-275 - HYDRO 2007 Deficiency: Main kitchen system: System is non compliant due to improper coverage of the lava chargrill and range with back shelf. Chargrill currently has 2x 1H nozzles, these need to be changed to 3x 1L nozzles and piped under the shelf for proper protection. Range currently has a 1H and a 2H, these need to be changed to 2x 2L due to back shelf. Lava Rock Char-Broiler (624 in. 2 (40257 mm 2) x 26 in. (660 mm) longest side maximum) Note: Synthetic rock charbroilers are distinguished by the use of lava, pumice, or synthetic rocks that are used for cooking. One nozzle is available for lava rock char-broiler protection: High proximity and low proximity. The 2L Nozzle (Part No. 551027) is used for high proximity lava rock char-broiler protection. This nozzle is a two flow nozzle. The nozzle must be located anywhere within the perimete


Nicholas L.

Nicholas L. Job Checkin

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 14196023 Correct system deficiencies Repair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Fire Suppression Repair The nozzles for the appliance protection are all outside the perimeter of the appliances. The fryer nozzles are not in the proper position. The griddle requires a second 11982 nozzle for its protection.the nozzles for the 6 burner (with back shelf)protection are not the proper ones. The nozzle for the griddle protection is not the proper one ( there is an upright broiler on top of the griddle). The nozzle for the upright broiler is not the proper one. All the pipe and conduit outside the hood is painted


Nicholas L.

Nicholas L. Job Checkin

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 14196023 Correct system deficiencies Repair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Fire Suppression Repair The nozzles for the appliance protection are all outside the perimeter of the appliances. The fryer nozzles are not in the proper position. The griddle requires a second 11982 nozzle for its protection.the nozzles for the 6 burner (with back shelf)protection are not the proper ones. The nozzle for the griddle protection is not the proper one ( there is an upright broiler on top of the griddle). The nozzle for the upright broiler is not the proper one. All the pipe and conduit outside the hood is painted


Michael S.

Michael S. Job Checkin


Michael S.

Michael S. Job Checkin


Michael S.

Michael S. Job Checkin


Michael S.

Michael S. Job Checkin


mark g.

mark g. Job Checkin


mark g.

mark g. Job Checkin


mark g.

mark g. Job Checkin


mark g.

mark g. Job Checkin


mark g.

mark g. Job Checkin


Michael S.

Michael S. Job Checkin