26 Hampshire Drive
Hudson, NH 03051
(800)244-7531

Local Reviews
for gorham, me


Job Locations
for gorham, me

Nicholas L.

Nicholas L. Job Checkin

Gas Station Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection GAS STATION - QTY 1 LIFT REQUIRED FOR INSPECTION ATD80 X16 GS TO BE DONE WITH FX FIRE EXTINGUISHERS - QTY 7 FX TO BE DONE WITH GS EMERGENCY LIGHT SPOT CHECK - QTY 18 REPAIR AS NEEDED EL TO BE DONE WITH GS


Nicholas L.

Nicholas L. Job Checkin

Gas Station Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection GAS STATION - QTY 1 IND50 x 8 2013 x 8 GS TO DO FX AT SAME TIME FIRE EXTINGUISHERS - QTY 5 FX TO BE DONE WITH GS EMERGENCY LIGHT SPOT CHECK - QTY 13 REPAIR AS NEEDED EL TO BE DONE WITH GS


Derek D.

Derek D. Job Checkin


Nicholas L.

Nicholas L. Job Checkin

Gas Station Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection GAS STATION - QTY 1 ATD80 X16 GS TO BE DONE WITH FX FIRE EXTINGUISHERS - QTY UNKNOWN FX TO BE DONE WITH GS EMERGENCY LIGHT SPOT CHECK - REPAIR AS NEEDED EL TO BE DONE WITH GS


Nicholas L.

Nicholas L. Job Checkin

Gas Station Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection GAS STATION - QTY 1 IND50 x 8 2013 x 8 GS TO DO FX AT SAME TIME FIRE EXTINGUISHERS - QTY 5 FX TO BE DONE WITH GS EMERGENCY LIGHT SPOT CHECK - QTY 13 REPAIR AS NEEDED EL TO BE DONE WITH GS Deficiency for Kidde/Badger IND-50 400lb: Gas Station System: XV Control head is on the top of the canopy and is not listed for outside use by the MFG. The control head will need to be placed inside a UL listed weather tight enclosure (will require an electrician to remove and reinstall wires in new enclosure). 3 IND-50 cylinders are due for hydrostatic testing. (all above pumps 5/6 & 7/8) Confirmed 3/26/18 NL


Nicholas L.

Nicholas L. Job Checkin

Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiency was found on order 13492816 One ATD-80 tank has lost pressure and needs to be serviced or changed out with a compliant tank. Repair of these deficiencies is essential to overall life safety. Please see attached quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Gas Station Suppression Repair Pyro Chem ATD-80 1280lb: Gas Station System: 1 ATD-80 cylinder over pump 3/4 has lost pressure and need to be serviced. (cylinder is closest to the store and on the pump 2 side of the beam) - repair


Michael S.

Michael S. Job Checkin


Michael S.

Michael S. Job Checkin