Job Locations
for milford, nh

Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Inspection KITCHEN SYSTEM - QTY 2 RG 6.0 RG 2.5 KS ALL INCLUSIVE Inspect small cafe system


Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Inspection KITCHEN SYSTEM - QTY 2 RG 6.0 RG 2.5 KS ALL INCLUSIVE


Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Installation install 2.5 gallon range guard system


Jim C.

Jim C. Job Checkin


Michael S.

Michael S. Job Checkin


Michael S.

Michael S. Job Checkin


Nicholas L.

Nicholas L. Job Checkin

GAS STATION - QTY UNKNOWN GS DO FX AT SAME TIME FIRE EXTINGUISHERS - QTY 7 FX TO BE DONE WITH KS EMERGENCY LIGHT SPOT CHECK - REPAIR AS NEEDED EL TO BE DONE WITH GS Gas Station Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection


Nicholas L.

Nicholas L. Job Checkin

Emergency / Exit Lights, Portable Extinguishers, and Gas Station Suppression Inspection EMERGENCY LIGHT SPOT CHECK - QTY 19 REPAIR AS NEEDED EL TO BE DONE WITH GS FIRE EXTINGUISHERS - QTY 4 FX TO BE DONE WITH KS GAS STATION - QTY UNKNOWN GS DO FX AT SAME TIME Deficiency: Gas station system is non compliant due to cylinders needing 6 year maintenance ATD75x4-ATD35x1 all are dated from 2012


Michael S.

Michael S. Job Checkin


Derek D.

Derek D. Job Checkin


Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Inspection KITCHEN SYSTEM - QTY 2 RG 6.0 RG 2.5 KS ALL INCLUSIVE


Jim C.

Jim C. Job Checkin


Michael S.

Michael S. Job Checkin


Nicholas L.

Nicholas L. Job Checkin

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 13849748 Main Line - Multiple pipe penetrations to hood are missing seals - Client Decision - Remove back shelf over range and current coverage can remain. If shelf stays in place re-pipe the nozzle coverage below shelf **If shelf is removed misc pipe material and some labor can be removed from below total - Relocate plenum nozzles and face all nozzle the same direction Cafe - Relocate plenum nozzle Repair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Fire Suppression Repair Both systems are missing penetration seals. Emt seals and threaded seals. Fryer nozzle was chaged to a LPF in cafe. Range needs nozzles to be rel


Nicholas L.

Nicholas L. Job Checkin

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 13849748 Main Line - Multiple pipe penetrations to hood are missing seals - Client Decision - Remove back shelf over range and current coverage can remain. If shelf stays in place re-pipe the nozzle coverage below shelf **If shelf is removed misc pipe material and some labor can be removed from below total - Relocate plenum nozzles and face all nozzle the same direction Cafe - Relocate plenum nozzle Repair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Fire Suppression Repair Both systems are missing penetration seals. Emt seals and threaded seals. Fryer nozzle was chaged to a LPF in cafe. Range needs nozzles to be rel