Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiency was found on order 15042253. Gas Station Canopy Suppression System All Kidde IND50 cylinders (4) are past due for the 12 year hydrotest services. This includes service swap cylinders, paint/prime service, new NFPA collars, new safety plugs and valve rebuild kits No k-class fire extinguisher in kitchen where fryer is located CLIENT RESPONSIBILITY: Contact fire alarm company and electrician to properly tie-in gas station XV control head. Currently there is no alarm or electrical shut down Repair of these deficiencies is essential to overall life safety. Please see the attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512 Gas Station Suppression Repair Gas station is non compliant due to system cylinders need hydro testing. This test must be performed every 12 year


Nicholas L.

Nicholas L. Job Checkin

FIRE EXTINGUISHERS - QTY 3 GAS STATION - QTY 1 Portable Extinguishers and Gas Station Suppression Inspection Deficiency: Gas station is non compliant due to system cylinders need hydro testing. This test must be performed every 12 years per NFPA. There is no fire alarm tied into the system. Pumps do not shut down apon system activation. Will need to add class k fx in kitchen due to auto fry system


Nicholas L.

Nicholas L. Job Checkin

Gas Station Suppression, Emergency / Exit Lights, and Portable Extinguishers Inspection GAS STATION - QTY UNKNOWN GS DO FX AT SAME TIME EMERGENCY LIGHT SPOT CHECK - REPAIR AS NEEDED EL TO BE DONE WITH GS FIRE EXTINGUISHERS - QTY UNKNOWN FX TO BE DONE WITH KS Deficiency for Pyro Chem ECH3 ATD80SBC: Gas station: System deficiency still exist. see previous paperwork.see pictures Also found One cylinder above pumps 5/6 has a leak and needs to be swapped. second cylinder in from store side of canopy


Nicholas L.

Nicholas L. Job Checkin

Portable Extinguishers Inspection FIRE EXTINGUISHERS - QTY 1


Michael S.

Michael S. Job Checkin


Derek D.

Derek D. Job Checkin


Berton Y.

Berton Y. Job Checkin

Portable Extinguishers Inspection


Berton Y.

Berton Y. Job Checkin

Portable Extinguishers and Emergency / Exit Lights Inspection


Berton Y.

Berton Y. Job Checkin

Portable Extinguishers Inspection


Brenda K.

Brenda K. Job Checkin

Annual fire extinguisher inspection at a fish and game club