26 Hampshire Drive
Hudson, NH 03051
(800)244-7531

Local Reviews
for raymond, nh

Rated 4.7 out of 5 stars based on 3 customer reviews

Great service

Jim was very helpful in solving our many issues.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Extinguisher Inspection

Well organized, informative, very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Helpful & Friendly

Chris was very willing to answer any questions or concerns regarding our fire pump & sprinkler system. When asked about having the company perform another service for us he suggested we go to the area in question so he could get a better sense of our need. Chris is a good representation of your company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for raymond, nh

Jim C.

Jim C. Job Checkin


Jim C.

Jim C. Job Checkin


Jim C.

Jim C. Job Checkin


Derek D.

Derek D. Job Checkin


Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Installation Installation of RG-4GM Deficiency: Improper quantity of heat detectors. One heat detector bracket is not secured to hood. Appliances are not properly protected. Control head is not properly mounted. Hydrostatic test on PCL240 overdue. System has been built using mixed generations of components (pre KK and KK1). Pull station is higher than 48" aff. Cylinder bracket for 240 is not a Pyro Chem manufactured part


Nicholas L.

Nicholas L. Job Checkin

4/11/18 per Troy he is awaiting some approval from their corporate office. Troy will give us a call when he receives approval from them. 5/8/18 left voicemail. Fire Suppression Inspection KITCHEN SYSTEM - QTY PYROCHEM WITH PCL-350 & PCL-240 LINKS AND NOZZLES COVERS INCLUDED Deficiency: Improper quantity of heat detectors. One heat detector bracket is not secured to hood. Appliances are not properly protected. Control head is not properly mounted. Hydrostatic test on PCL240 overdue. System has been built using mixed generations of components (pre KK and KK1). Pull station is higher than 48" aff. Cylinder bracket for 240 is not a Pyro Chem manufactured part Deficiency: All previous deficiencies still exists: Improper quantity of heat detectors. One heat detector bracket is not secured to hood. Appliances are not properly protected. Control head is not properly mounted. Hydrostatic test on PCL240 overdue. System has been built using mixed generations of components (pre KK and KK1). Pul


Jim C.

Jim C. Job Checkin


Jim C.

Jim C. Job Checkin


Nicholas L.

Nicholas L. Job Checkin

Portable Extinguishers and Fire Suppression Inspection FIRE EXTINGUISHERS - QTY 10 FX ALL INCLUSIVE KITCHEN SYSTEM - QTY 1 AMEREX KP-600 (TWO CYLINDERS) KS ALL INCLUSIVE Deficiency: System is non compliant due to improper coverage of the first range on main cooking line. Range is not completely under the protective hood. Needs to be moved to the right. see pictures. Also it is not protected properly. Once the range is adjusted under the hood properly we will need to adjust the nozzles accordingly. Plenum nozzles in rear hood need to be relocated to the side and not down the middle. Duct nozzle needs to be replaced in that same hood. Both ranges under that hood are improperly protected. Nozzles will need to be changed and adjusted per manufacturer specs. Customer is looking into down sizing the range that is not under the hood from a 6 burner to a 4 burner.


Jim C.

Jim C. Job Checkin


Derek D.

Derek D. Job Checkin


Berton Y.

Berton Y. Job Checkin

Portable Extinguishers and Emergency / Exit Lights Inspection


Berton Y.

Berton Y. Job Checkin

Portable Extinguishers Inspection


Berton Y.

Berton Y. Job Checkin

Portable Extinguishers Inspection


Nicholas L.

Nicholas L. Job Checkin

Fire Suppression Inspection KITCHEN SYSTEM ANDUL 6.0 GALLON SSBD 2X HYDRO: (1) 2006, (1) 2013