Joe was informative and professional in how he helped us with our emergency today. I am very appreciative for being able to work with someone that helps me understand the problem and how it can be avoided in the future. He is a wonderful asset that represents United Fire at a high level. Thank you.
Tony not only reset our dry pipe valve but correctly assessed our system problems and corrected all issues. We had 3”. Of standing water in our basement classrooms and he let us borrow his sump pump to evacuate all the water. His caring compassionate and professional approach made a huge difference as we cleaned up the mess. Thanks Tony your the best.
We need to be on an automatic call yearly. I can not comment on the cost because I do not know the amount.
Andy and his associate came in, reconfigured the fire suppression system to match our new range and reconnected it. It was a real pleasure working with Andy. He is friendly, helpful and patient with all questions. It is clear he is an experienced professional. He is welcome here at Sunnyside anytime.
Brian was awesome! I liked how he had communicated with me every issues that hindered him to complete the job.
Joe was very fun and easy to work with. The training was to the point, and very helpful. Thanks!
Response from United Fire:
Thank you for the great review Rhiannon! We appreciate the opportunity to work with you and your team on the fire extinguisher training.
Inspected the reported issue with their fire sprinkler system. Upon assessment, I found a faulty pressure gauge and a minor leak in one of the branch lines. I replaced the damaged gauge and sealed the leaking pipe section. After testing the system, everything is now functioning correctly and within safety standards.
Completed follow-up inspection on previously identified fire safety deficiencies. Re-examined five fire doors with faulty self-closing mechanisms. Verified installation of new door closers rated for 15-20 lbs closing force. Tested emergency lighting units, confirming 90-minute battery backup capacity. Inspected newly installed fire stops in cable penetrations, ensuring proper intumescent material application. Reassessed sprinkler head obstructions, confirming minimum 18-inch clearance restored. Evaluated updated fire evacuation plans for compliance with NFPA 101 requirements. Documented all corrective actions in comprehensive report, noting full compliance achieved. Recommended quarterly self-inspections to facility manager for ongoing fire safety maintenance.