Found that system is not operating due to restricted plumbing the drain line connect to. Recommend to have plumber service plumbing that ac system connects to.
Performed ac services for a 2018 Lennox system we installed. Replaced filter at time of services. Drain lines are clear at this time. Refrigerant charge for system is good. Power distribution tested good. Water washed condensing coil. System operating as expected.
In arrival found primary drain backed up. Cleared drain and tested flow. System working properly at this time.
Drain primary cleared at sink with vacuum. Moisture will evaporate naturally from attic. New customer coupon
Low refrigerant pressure on arrival. No leak detected. Valve caps loose. Pcc pricing given for customer satisfaction. No warranties on refrigerant. Recharge will make an active leak worse.
A/c Tune Up Performed on 2 a/c systems. Find Tuned Charge.
No cool. Inspected both systems operation. Did not perform tune up. Found one system low on refrigerant and leaking from equipment. Other system has restriction in refrigerant cycle causing for lack of cooling. Spoke with customer about issues with equipment. Returning to go over repair options.
Spring 2 tune up. Checked all electrical and clean out contacts. Checked pressure, found u/s condenser power distribution has failed spoke to customer about it the only reason it still comes on is because it has a start assist Checked drain line to ensure it is free flowing added pan treatment to condensate line. All operations are operating Home owner replaces media filters
Spring 2 tune up. Checked all electrical and clean out contacts. Checked pressure, water washed condenser coil. Checked drain line to ensure it is free flowing added pan treatment to condensate line. All operations checked out okay at this time No media filter in system
Spring 2 tune up. Checked all electrical and clean out contacts. Checked pressure, water washed condenser coil. Checked drain line to ensure it is free flowing added pan treatment to condensate line. Found east side equipment low on r-22 1990 amana not operational spoke to customer about age and reliability. west side equipment is from 2004 Goodman r410 it is operating.
Preformed a quality AC tune up on two systems that we did not install. Customer replaces his own media filter. No air purification or surge protection to inspect. All AC operations are operating properly at this time.
2017 electric air handler 3.5 ton system. Drains open and flowing. Negative refrigerant leak detection. Discussed issues with age and reliability. No air scrubber to inspect.
Performed precision AC tune up. Checked operating refrigerant pressures. Adjusted refrigerant charge to ensure peak performance and efficiency. Tested power distribution system and corresponding starting components. Verified proper amp draw; optimal. Media filter is due for replacement 20x20x5. Purged primary drain line to ensure no blockage or obstructions. Used alkaline treatment to reduce bacterial growth within lines. Verified temperature differential across indoor coil within desirable range. Washed outdoor coils thoroughly to maintain heat rejection. All checks are good at this time system. System is currently operating within desirable specifications
Performed precision AC tune up. Checked operating refrigerant pressures. Found system low on refrigerant. Determined this was result of leak present inside evaporator coil upstairs. Tested power distribution system and corresponding starting components. Verified proper amp draw; optimal. Temperature differential across indoor coil below target due refrigerant loss. Purged primary drain line to ensure no obstructions. Used alkaline treatment to reduce bacterial growth within lines. Replaced existing media filter 20x25. Returning to replace Evap could under MFG. Will need to level condenser when we return to replace evaporator coil.
Inspected duct work for air flow issues for guest bedrooms. Spoke with office and her about possible solutions. Returning thursday to add manual dampers to system