Courtesy refrigerant check for system due to concerns of a potential leak. Refrigerant charge is good and holding at this time compared to last visit when system was recharged.
Replaced all 3 damper motors. 2 are for down stairs zone and the other is for up stairs zone. Tested motors and they are responding as expected.
Ac services for 2 2001 Rheem systems Customer recently had home warranty out because up stairs refrigerant line was freezing. Home warranty informed them.it is due to loss of air flow from plugged filters. Down stairs high pressure switch has been bypassed. Filters are over due at this time. Also found that up stairs system is operating low on refrigerant. Power distribution had been replaced recently and tested good for both systems. Water washed condensing coils. Condensing coils have become very brittle and flaking off with water wash. Verified that drainage is flowing freely at this time.
Unable to clear drain lines due to years of build up in drain lines. Recommend replacing drain lines and running them along side of home. Existing drain lines already run out side
Performed ac maintenance. Found system in working condition. All electrical components working properly. Pressures and temperature good. System is working at this time.
Uppon Arrival found up stairs 2012 rheem with 2019 allstyle coil not cooling due to low refrigerant charge. Confirmed leak in evap coil. Verified warranty and scheduling for warranty coil replacement for up stairs system.
Performed ac services for 2008 and 2001 american standard r22 systems. Both systems operating with good SC but low SH caused by low air flow from undersized returnes and impacted coils. Verified that drainage is flowing freely at this time. Water washed condensing coils. Discussed concerns of reliability due to age and condition of systems. Confirmed that starting components are within manufacturers specifications.
Performed ac services for a 2010 carrier system. Found system low on refrigerant and confirmed a leak in the evap coil. Water washed condensing coil. Verified that drainage is flowing freely at this time. Power distribution good at time of service.
Performed ac services for a 2015 trane single stage system with 2 zones. Replaced customer provided filter at time of service. Verified that drainage is flowing freely at this time and provided drainage treatment tablets. Water washed condensing coil. Verified that starting components are within manufacturers specifications. System operating as expected at this time.
Performed ac services for 2 2017 lennox systems with 2020 warranty coils. Verified that drainage is flowing freely at this time. Filters in home due. Confirmed that starting components are within manufacturers specifications. No air/coil sanitation device to inspect. Systems operating as expected at this time.
Performed ac services for one system. Water washed condensing coil. Verified that drainage is flowing freely at this time. Filter good at time of services. Found power distribution not within tolerance.
Uppon Arrival found system with main older style federal pacific tripped. System starting components within manufacturers specifications. Refrigerant charge for 2008 r22 system look good. Starting apps at 24 and recommended start assist system. Informed customer that issues may also be failing breakers.
Outside system is a 2015 American standard single stage and furnace is a grande late 2000. Home owner have home insurance. When I spoke to her about age of system. Just had attic Reno done
Performed ac service for a 2021 lennox air handler system we installed. Raised some duct work on back side of system for accessibility purposes to attic fan. Water washed condensing coils. Verified that drainage is flowing freely at this time. Filter due for replacement and customer said he will do so himself. Confirmed that starting components are within manufacturers specifications.
No issues with system at time of services. Collected 79.00$ for today's services and customer will pay remaining balance of 80.00$ 3-25-22 for annual PCC membership and recieved approval from troy due to his current financial concerns regarding his father's passing recently.