Thank you Keith Lee for your timely help in my pinch! You did an excellent job, and were a pleasure to do business with! I highly recommend Keith to anyone who needs help with their plumbing!
Shower valves leaking when turned on. Rebuilt 2 Delta shower valves with new seat and springs
Furnished and installed new American Standard toilets. Reflanged master bath toilet and installed new cutoff valve on hall bath toilet
Low water pressure, removed diverter on shower valve and cleaned debris. Also cleaned debris from shower heads and washing machine
Excavated waterline at meter and installed 3/4" PRV (pressure regulator) on waterline. Set pressure to 60 PSI. Checked other plumbing
Expansion tank leaking. Checked pressure at 90 PSI. Replaced expansion tank and plumbing pressure regulator (PRV). Also repiped section of galvanized water pipes with copper and lowered gate valve.
Delta kitchen faucet leaking. Rebuilt faucet and installed new springs and washers. Checked other plumbing
Ran new polyethylene waterline from meter to home. Repiped section of galvanized waterpipes at house with multiple tees and tie ins. Installed pressure regulator (PRV) and new cutoff valve. Cleaned hot water stem on plumbing valve on bathtub.
Hot stem on garden tub bathtub valve constantly leaking. Found that seat is scarred. Ground seat and replaced washer. Checked other plumbing items
Replaced washer on garden tub faucet. Checked other plumbing
Repaired natural gas leak on gas line at commercial property. Checked other plumbing items
Drains backing up to septic tank. Attempted to snake drain. Gave estimate to make repairs to plumbing