Hydro jet Main sewer line through cleanout in front yard out to city
Backed up mainline. Cabled from clean out cleared stoppage camera afterwards discovered rootball. Line needs hydrojet to clear obstruction
Backed up kitchen drain cabled form clean out and cleared stoppage
Rebuild shower valve with customer supplied parts
Install moen shower rebuild kit in brushed nickel
Locate leak in water main in front yard. Excavate to expose leak. Cut out bad section and repair with new pipe. Test and back fill.
3/4" gas line. Re-locate gas feed for range to approved location.
Install two tubs / shower valves including rough in, set and finish. Install one cast iron tub. Including waste over flow and trap. Install two lav faucets, including new shut off valve and supply lines. All fixtures Moen Chateau Chrome. Cast iron 60"x32", white.
Re-pipe house. Hot and cold potable water lines. Replace all Angle Stops and Supply Lines. Replace all Emergency Shut-Off valves and Hose Bibbs.