Arrived at location on 6/8/21 to check on fryer. Kitchen staff pointed out middle fryer. Checked resistance across coil on gas valve, got 10 ohms. Checked thermopile output, got 400 mv. Proceeded to replace thermopile and found pilot burner hood falling off body. Will need to order burner hood and thermopile. Will return and replace. QWP authorized by Brent Meckes. Returned 6/9/21 installed new thermopile and pilot on unit. Took mv readings and got 550 millivolts. Unit now operating properly. Placed unit back in service.