Service C.

Service C. Job Checkin

Found Prep Table unit pressures low, I added 134A to bring pressures to normal, Unit came down to temperature and cycled off, I checked for leaks with leak detector and found evaporator to be leaking, unit will need evaporator replaced, customer would like a quote on repair.


Service C.

Service C. Job Checkin

Installed Reach-In Cooler fan and checked door for condensate issue. Door condensate heaters are working but the Kitchen has no AC and is very humid and that is why doors are condensing


Service C.

Service C. Job Checkin

At location took call. I found Holding Cabinet top and bottom door gaskets falling apart and pull handle top broken bottom broken completely off and also trim panel busted. I will order parts and return to make repairs. 6/30/20 Arrived on site and installed replacement door gaskets, handles and top trim. tested unit OK for use.


Service C.

Service C. Job Checkin

Found Reach-In Cooler compressor with locked rotor. Tried to start unit and its pulling close to 50 amps. LRA is 51 amp's. Customer requested a quote for a new compressor replacement, and a complete condensing unit replacement. All information has been sent back for quoting purposes.


Service C.

Service C. Job Checkin

Replaced left door gasket on Reach-In Cooler


Service C.

Service C. Job Checkin

arrived, stated VHL Range unit is leaking grease everywhere, propped up griddle plate, found signs of leaking around seams of plate, will quote new griddle plate.


Service C.

Service C. Job Checkin

Combi Oven - found flame sense wire not connected to the module. I did reconnect it and checked ops, okay, ready to use.


Service C.

Service C. Job Checkin

Customer stated Holding Cabinet unit was not heating, checked and found burnt wires going to element. Made repairs and unit now heats. Noticed when power was off 60v still going through SSR, needs to be replaced, will return with parts. 4/17/19 Pulled unit out. removed old SSR AMD replaced with new tested. no amp draw when power is off. turned on and had 11.3 amp draw, ran unit to set point. Okay for use.


Service C.

Service C. Job Checkin

Customer stated DEL Table unit isn't heating as well as the other wells, will replace left two infinite switches. 10-09-18 Arrived, shut breaker off to unit. Replaced left two infinite switches, reassembled. Unit now tripped breaker immediately. Put old switches back in, breaker doesn't trip. Swapped around new switches, found new switches bad. Contacted factory to verify correct wiring and have correct part number. Will order new switches and return. 10-10-18 Arrived, installed two left side switches for wells. tested, okay.


Service C.

Service C. Job Checkin

Arrived. Cress Core Holding Cabinet unit was off in the hallway. Removed top and replaced element, hi limit, and SSR, tested. Unit now heats properly and stops heating when you turn it off. Okay for use.


Service C.

Service C. Job Checkin

Arrived and ISE disposal was locked up. Unjammed unit and tested it. Found unit has bad bearings. Will provide quote on new unit


Service C.

Service C. Job Checkin

Arrived. starting deliming process. pouring delimer into cavity of steamer. turned on and allowed to fill rest of way with water. heat up partially to descale inside cavity. allow delimer to sit in steamer for 30 minutes. drain water and delimer from unit. fill back up with fresh water, turn on and allow to heat up. flush water through unit a few times to get rid of delimer residue. remove components from inside steamer and wipe off residue. reassemble and turn unit on. okay for use.


Service C.

Service C. Job Checkin

Found unit was on. Spoke with customer, stated unit won't steam. Checked while it was on and had 4.3 micro amps. Drained both top and bottom boilers and refilled and both compartments, started to steam and time down when ready t stat was made. Drained and filled again. Noticed some lime floating in probe housing. Will set up a time to come back to delime first thing in the morning. Unit is okay for use at this time


Service C.

Service C. Job Checkin

Replaced burner and gasket and ignition module and bus cable and replaced old steam hose i did calibrate burns to 9.4 Co2 and 28ppm co all ok and ready to use.


Service C.

Service C. Job Checkin

Door latches are broken. Will obtain parts. Also bottom oven needs new latches and customer would like 4 spare latches. Will obtain parts and return. Joseph the chef says order QWP. (Expedited Freight) 7-26-2017 Returned and replaced oven door latches and left 4 piece for their spare parts per Wick. Checked operation. OK to use.