1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for lancaster, pa


Map of Lancaster PA
Mark B.

Mark B.


Job Checkin

Arrived at location on 3/28/22 - Unit dripping from under the base panel while I clean mode. Found water dripping from door gasket. Found water regulator is coming apart and has been leaking water. I will obtain parts and return. Returned to location on 4/7/22 - Replaced the water regulator assy and replaced the door gasket. Found steam leaking at the door. Gasket does not sit well where the cabinet is welded above the center above the door. Also adjusted the bottom of the door cover so water would not leak from the door drain hole. I did snake the drip tray drain tube and ran a clean cycle. I will obtain another gasket and return. Returned to location on 4/21/22- Replaced the door gasket I checked ops. Ok ready to use.