Mark B. Job Checkin

Arrived at location on 6/5/21 to check on creamer dispenser. Creamer dispenser is not turning on. stated we were out other day to fix. Checked unit over, checked plug and outlet, unit is plugged into power strip. Power strip is in poor condition and tripped. Reset and unit turns on and begins cooling down. Remove power strip. Plugged unit directly into wall. Informed manger not to use power strip on this equipment. Tested unit and all sizes are dispensing, is operational. Unit is cooling down. ok for use.


Libby D.

Libby D. Job Checkin

BUNN COFFEE MACHINE (left unit drive through)- 4/26/2021-Greg M - manager oked repair of hose leak on a unused hose behind the ice cream machine. I did repair the leak by capping off the hose with parts purchased locally


Service C.

Service C. Job Checkin

Removed and replaced Reach-In Freezer perimeter heater and gasket base. Ensured all seams are sealed and system is operating properly at this time.


Service C.

Service C. Job Checkin

arrived, stated Pizza Oven unit is not heating up at all. pulled unit out from wall. disassemble and remove covers. hi limit not tripped. hi limit is closed, verify continuity. turn unit on, both contactors latch ok. checked and have 212 volts to element, no amp draw. bad element. will quote. 11/27/20 arrived, started disassembly. remove front door on unit, remove conveyor assembly and fingers assemblies to access element. remove element brackets and covers, remove old element (does have a hole burned through it). install new element. clean out debris inside oven (crumbs, dirt, etc). reassemble. turn on, 31 amps on element now. allow to heat up, ok for use.


Service C.

Service C. Job Checkin

Found Dishwasher timer controller is bad, unit not energizing the fill solenoid. I will obtain parts and return. 10/5/20 Replaced the computer controller, I checked ops, okay, ready to use.


Service C.

Service C. Job Checkin

Arrived, stated right side of right grill platen doesn't go down enough. not cooking product correctly. found platen too high. unable to correct in gap calibration. adjusted lower limit switch to get platen to lower further. level platen. cook product, temping well. okay for use.


Service C.

Service C. Job Checkin

Found Reach-In Freezer evaporator drain pan and evaporator iced up. Put unit in defrost and amp draw was 5 amps, heaters are working. P trap in the drain line is not clogged but there may be something blocking the hole in the drain pan. Will leave unit off to thaw and return tomorrow to check it out. 11/14/18 Found drain line was clogged. Removed line cleaned out the clog. Pulled drain line heater farther into drain line. Heater is working. Poured water into drain pan. All drained out. Freezer is down to temp.


Service C.

Service C. Job Checkin

Took call while on site. Toaster unit is not working. Checked and found cooling fan not operating, had voltage to it. Unit does heat and belt works. Unit is not okay for use until we return with parts. 7-6-18 - Arrived, removed side cover and replaced cooling fan (left side). Reassembled and plugged back in. New fan runs, Allowed unit to heat up. Unit okay for use.


Service C.

Service C. Job Checkin

Arrived. checked Drive Through Windows operation. unit seems to slide ok but latch is damaged. there are multiple kinds of latches installed. contacted factory and spoke with Jeff. he stated the latching system for the window is discontinued for this window. he said the window was probably installed 23 years ago. he suggested we either make the window work with the hardware installed or try to obtain something similar to what's already installed. obtained a window lock locally and installed. unit now latches and locks. also cable system is missing on window. will obtain new and return. 7-3-18 - Returned. installed new chain and pulley system. lubricated moving parts. unit is ok for use at this time.


Service C.

Service C. Job Checkin

Found safety valve for burner #2 isn't working. Doesn't close. Need to order a new valve. Will order a new valve and return. -- *Spoke to factory and part for grill is unavailable. Grill is no longer safe to use. -- Called site and left know unable to finish repair. Suggested replacement unit. Close call. Bill customer.


Service C.

Service C. Job Checkin

Found actuator broken at the plastic upper housing cracked off on the left side of grill. Replaced the actuator. Found lift arm bar mounting blocks missing. Bolts and blocks out of position for unit to work correctly. Will also need upper limit switch bushing and bolts. Will get quote to repair. Did put mount block up so it won't break the actuator. Returned and replaced frame, pillow blocks, bushings, screws, nuts and bolts. Repaired per quote. **Travel Charges billed on WO#107210


Service C.

Service C. Job Checkin

Found temperature set point only 215 on Electric Oven. Somehow it changed. Did reset temperature set point to 375. Checked elements. All OK. Checked operation. OK and ready to use.


Service C.

Service C. Job Checkin

Found pump bad on fryer. Did replace the pump and o'rings on the pick up tube. Checked operation. OK and ready to use.