Mark B.

Mark B. Job Checkin

Arrived at location on 11/10/21 - Examined unit. Booster unit on and working. Wash temp 170, rinse 184. Ran multiple racks through and temp dropped after about 15 racks. Pressure too high water temp too cold. Dale will replace the pressure reducing valve and run hot water before using machine to get 120 degree water up to temp before using. Booster pulling 48a per leg, cycling properly. Machine is working properly otherwise.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/11/21. Upon arrival unit was at 82 degrees. Found the condenser on the roof, the sight glass was empty compressor was running, discharge hot, suction not cold. The refrigerant is R449A. I charged the unit up with R449A the sight glass is full and the temp is at 0 degrees They have a leak, but they are good to go for now.


Service C.

Service C. Job Checkin

Examined left fryer. pilot not lit. found pilot knob broken on valve. unit has pilot linkage. need 2 knobs. was able to get pilot to hold. Will order knobs and return. 8/21/20 Installed gas valve knobs on valve and extension. tested. good to go


Service C.

Service C. Job Checkin

Replaced touchscreen and overlay on electric Oven. Tested unit, operating correctly at this time. Customer wanted unit looked over. When removing wires from power switch, found switch terminals overheated. Customer would like power switch replaced to prevent future downtime. Note: will order switch on new work order, this repair complete.


Service C.

Service C. Job Checkin

Examined Oven unit, checked all fuses and safeties, 25 amp draw on element checked finger placement, let run, unit working at this time.


Service C.

Service C. Job Checkin

Customer would like middle and left faucet replaced on Coffee Machine. customer also stated water not going over 180 degrees. waited for unit to heat. water at 185 and still heating. will order parts and return. 1/22/20 removed and replaced middle and left side faucet assemblies. tested. good to go


Service C.

Service C. Job Checkin

examined Convection Oven unit, found 3 way switch bad and changed it, checked both door switches, okay, found 1 terminal broken and replaced - also found a hole in gas line behind switch - will order new part, verify temp after repair. 10/28/19 removed and replaced valve to burner tubing and connectors. tested. no leaks. good to go


Service C.

Service C. Job Checkin

Checked out the Ice Machine unit. Had to run new drain lines. The customer wanted the lines installed with hose so they could move the machines around a little without the drain coming out. Got permission to go to the hardware store to get supplies. Ran the drains and hooked up the water supply. Tested and the unit is working.


Service C.

Service C. Job Checkin

Examined Gas Fryer unit, found left side extension rob knob broken and right valve hard to turn. swapped right knob over to left and lit pilot. was able to get right side to light but valve sticks and is difficult to turn. right valve should be replaced. will order parts for right side and return gas shut off is NOT behind fryer. will need to make sure work is performed before 3:30 so Bob can show tech where gas shut off valve is located. 2-1-19 Removed and replaced right side gas valve, thermocouple, and rod extension knob. tested. unit lit and cycled. good to go


Service C.

Service C. Job Checkin

Examined Steamer unit. Found door latch bad. Removed and replaced door latch. Gasket in poor condition, flipped gasket over. Also found blower motor not running. Found lead off relay. Reattached, motor running. Note: unit should have door gasket replaced.


Service C.

Service C. Job Checkin

The customer said that the Walk-In Cooler unit would freeze things, then not turn on until 45 to 50 degrees Fahrenheit sometimes. Replaced the temperature control. While testing got a little bit of oil on my finger when the flare nut on the compressor was wiped. Got gauges and a leak detector. Had about 12 psi on the suction side. Leak tested the fitting but found no leaks. Did add about one once of hot shot generation two. Adjusted the thermostat to open at 34 degrees Fahrenheit and it closes at 39 degrees Fahrenheit coil temperature. The customer can adjust the temperature control to whatever temperature they want to keep the product at.


Service C.

Service C. Job Checkin

Removed and replaced both Grill outer thermostats and lights. Tested, is good to go.


Service C.

Service C. Job Checkin

Examined unit and found convection oven blower motor will not run. Will order a new blower motor. 6-4-18 Replaced main blower assembly and tested units, door switch will not shut blower off when door is open. Did not have switches in truck. Customer will call if they want switches replaced.


Service C.

Service C. Job Checkin

Found customer had well repair and found both mini pilots blocked. Will order pilot. Don't know if anything else is not working at this time. QWP (expedited freight) 4-11-17 Removed and replaced 2 thermocouple and pilot assemblies. Tested, unit working.


Service C.

Service C. Job Checkin

Examined ISE Disposer unit. Found solenoid open. Cut power. Stayed open. Will order new 1/2 in 24v solenoid and return. -- Removed and replaced water solenoid. Tested good. 9-8-16