Arrived at location on 4/18/23 - I arrive on site and Alexed show me the unit. I cleaned the burners and replaced the flame sensor. After putting the unit back together and running the unit, it came up to temperature. I checked the flame current. 3.8- good oven temperature within 25 degrees. The unit is in service and job is complete.


Service C.

Service C. Job Checkin

2/3/21 Oven is off. Checked fuses. All ok. Turn on and E101 Magnetron Failed is displayed. Checked filter. Was dirty. Cleaned and put filter back in. Unplugged oven and removed back and side panels. Check both mag filaments and stats. All ok. Removed mags from wave guides. Antennas are ok and no burn marks or discoloration. Checked waveguides and they are not contaminated. Put mags back on. Checked transformers. Both ok. Getting good readings. Caps and diodes are ok. Plug in and turn on in diagnostic mode. Ran each mag individually and got 8 amps/mag. Ran both mags together and getting 16 amps. Exited visual view and turned on oven to preheat. Heated to set temp of 525°. Came out of preheat. Had customer run product through. Came out ok. Getting 16 amps during microwave cycle. No errors are displayed. Cannot duplicate failure. Most likely dirty filter caused issue. Back in service.


Service C.

Service C. Job Checkin

Checked ISE Disposer unit wasn't hooked to sink but was hooked to power. looked inside and plate didn't move by hand. searched for obstruction in teeth. did not find any thing that would make plate not spin. put socket on plate nut and I did get it to spin some but it was very hard. turned power on and turned on. tripped thermal over load. motor is seized and top bearings grinding when I spun by hand. cost of repair exceeds value of unit. Unit has been down for some time now per Carol. unit is down and needs replaced. we will quote them a new unit installed.


Service C.

Service C. Job Checkin

Steamer unit shut down when I arrived. turned on and let fill when it came to reset pushed reset button,nothing happened. checked main valve it was in pilot mode. put to on and burner lit. let come to pressure was shutting off at 12 and overriding to 14. explained to her if they are using both steamers and then shop both at once it could override to 15 or 17 psi. pop off opens at 15. turned bottom cab. on and let pressure go down ,burners came back on at 9psi. set to on at 7 psi off at 10 psi. they are not using kettle. will be sufficient amount of steam to cook with. unit operational job complete. no leaks present.


Service C.

Service C. Job Checkin

Arrived on site to check Groen steamer. Customer said unit would intermittently shut down and would have to restart unit. Brought steamer into operation but, could not duplicate customers problem with unit. Did find operating pressure pushing hi limit pressure of 15psi at 14.5psi. Also found air vent not closing and seating properly, allowing steam to drain allows flowing. Removed water level probes and found heavily corroded, cleaned as best as possible. Operating pressure is varying between 10 and 14.5 psi. Tried adjusting operating pressure switch with no response, Pressure not changing, will obtain new probes, pressure switch and air vent, return and replace. steamer in service


Service C.

Service C. Job Checkin

Found- High temp. safety tripped. Reset safety and ran unit till thermostat satisfied. Wash temperature holding between 155F and 160F. Rinse temperature at 185F, unit operating properly.