found warming cabinet fan motor is missing and temperature gage is broken will order parts: part number fan 338-60030-00 - gauge 344-27869-00 10/28/20 replaced fan motor and thermometer, checked overworking okay
Saw where elements had got very hot at one time and discolored the RAN Drop In Hot/Cold tub. Checked over wiring and connections, all seem okay. Ran unit and cycled a few times, could not recreate problem. Will order new thermostat. 9/13/19 Removed hot temp control and replaced, tested okay.
Removed cardboard gasket on top of rubber gasket under sink. Resealed flange with plumber's putty and tightened up with a plumber's flange wrench. All drain flanges were loose, and all drain levers were loose.