Job Checkin

Arrived. Dishwasher unit was running. checked and rinse temp wasn't making. found pressure set at 25. adjusted down to 20. ran and unit dropped to 145 for rinse temp randomly. swapped rinse thermistor for booster thermistor and unit is warming ok at this time. will order replacement thermistor. along with new contactors. unit working ok until we return. 8/20/20 Installed contactors and probes. Ran unit, checked amp draw. Missing leg, found fuse blown at disconnect. Got new fuse from Mike. Now checked at 25 amps. Ran uni,t tested ok.