Awesome Service

Technician was most pleasant. He performed the service on both of my units with professionalism and was extremely neat.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast response

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Installation

I was very pleased with the installation of new ducting to supply a newly enclosed sunroom. Chris was his usual great worker and completed the job to my satisfaction.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!!!

Professional and courteous. 5 star service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Dennis is the Best! But I have to say that all techs are very good. always on time, knowledgable, and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for woodstock, ga

Alex S.

Alex S. Job Checkin

Replaced 4-16x25x2, 2-20x35x2 filters and a AX36 belt. Systems are working properly. Pics uploaded, need extension ladder every visit Sending invoice to email for payment


Alex S.

Alex S. Job Checkin

2 system CCM- Checked heating operations of upstairs 1993 Trane, and Main level 2019 Rheem furnaces. Replaced 2-16x25x1 filters, Checked capacitor outputs and amp drawls, Inspected heat exchangers, Checked delta T, triggered safety switches, Cleaned flame sensors, Brushed burners, and cleared drain line. Systems are operating properly at this time. Pics uploaded Customer would like to schedule to add a Pan safety switch(upstairs), replace weak 5mfd capacitor(upstairs), replace corroded flu pipe for the main level system, and add a carbon monoxide detector in home.


Joseph R.

Joseph R. Job Checkin

During today’s visit, performed inspection and maintenance on one basement furnace unit. Inspected ductwork and flue pipe for leaks. Inspected overall cleanliness of the blower and burner compartments. Customer has already changed the 16 x 25 x 5 filter. The customer will be supplying their own filters. Inspected flame sensor, igniter, pressure switches, and burners. Inspected blower and inducer amperage. Performed ignition sequence on the furnace and inspected flames. Inspected temperature heat rise, which is in the ideal range. The system is performing normally at this time. The customer has opted to sign up for the comfort club membership and will be paying monthly. Photo attached.


David J.

David J. Job Checkin

Performed 1 natural gas furnace maintenance. Replaced 16x25x4 media filter for system. Cleaned and checked all furnace components, inspected burners and heat exchangers. Furnace is functioning properly.


Jordan E.

Jordan E. Job Checkin

Replaced eco zone control board under full pnl


Alex S.

Alex S. Job Checkin

Warranty- Upon arrival found 3 damper faults on thermostat, I inspected system and reset power. System is heating and throwing no codes at this time. Made customer aware I will be ordering the EWC econet zone board. It may be throwing false codes periodically. Pics uploaded Will be ordered from supplier


David J.

David J. Job Checkin

Checked a/c unit to make sure that it wasn’t damaged or had loss of refrigerant. System is still full of refrigerant and has no damage to the unit. It had only caught the a/c pad and slightly moved it.


Jordan E.

Jordan E. Job Checkin

Performed maintenance on furnace filter do not need to be changed homeowner said she changed it recently cleaned off flame sensor checked all electrical components for broken or loose connections checked amperage on fan motor everything is running normal at this time


Jordan E.

Jordan E. Job Checkin

2 system PM renewal Upstairs- checked heating operations of system. Replaced filter, checked capacitor output and amp drawls, cleaned flame sensor and burners, triggered safety switches. Unit is operating properly at this time. 16x25x4 Main- checked heating operations of system- changed filter, checked capacitor output and amp drawls, checked Freon levels and auxiliary heat, triggered safety switches and defrost. Unit is operating properly at this time. 16x25x4. Customer provides filters


Michael  J.

Michael J. Job Checkin

120 V electrical switch to furnace had failed. Technician installed duplex switch with receptacle. Furnace is now operating normally.


Jordan E.

Jordan E. Job Checkin

Performed 3 system commercial heat maintenance replaced 2 20x35x2 filters and 4 16x25x2 filters cleaned flame sensors and pressure tubes tested all electrical components inspected heat exchangers all systems operating properly at this time


Jordan E.

Jordan E. Job Checkin

ZERO percent interest financing for 36 months with approved credit


Jordan E.

Jordan E. Job Checkin

I performed a maintenance on one system in the attic I cleaned out the industrial motor port where the tub for the pressure switch and the system came on and started to run check the blower motor amperage and the compaster, cleaned the flame sensor and changed the filter 16x25x1 I also did the same for the system in the basement beside changing the filter. The systems are running and operating like they should be at this time.


Michael  J.

Michael J. Job Checkin

Warranty, Customer has part, and labor warranty Codes displayed by upstairs master thermostat. All codes are zone damper faults. Technician found bypass damper physically restricted/Not able to close fully. Flex duct liner and insulation is getting caught on external damper stops. Material is getting pinched, preventing damper from closing all the way. Removed all material and cleared area of movement to prevent future issues. Photos of all codes uploaded.


Jordan E.

Jordan E. Job Checkin

Furnace- Checked heating operations of system. Replaced filter, checked capacitor output and amp drawl, trigger safety switches, cleaned flame sensor, cleaned burners, and cleared drain line. system is operating properly at this time. Heatpump -Checked operations of systems. Replaced filters, check capacitor outputs and amp drawls, checked refrigerant levels and auxiliary heat, triggered safety switches and defrost modes, and cleared drain lines. Systems are operating properly at this time 16x20x1. 2-16x25x1.