Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Rheem AC unit. I checked all the of the system and found no issues. I let the system run and there were no issues at this time. The system is operational upon departure.

I completed a diagnostic on a Rheem AC unit. I checked all the of the system and found no issues. I let the system run and there were no issues at this time. The system is operational upon departure.

Hassan H.

Hassan H. Job Checkin

I installed a Carrier 80% 90,000 BTU Gas Furnace and a Carrier 13 SEER 3 Ton Air Conditioner. The customer's upgraded to Carrier systems. I cycled and monitored the systems and they are both operational at this time.

I installed a Carrier 80% 90,000 BTU Gas Furnace and a Carrier 13 SEER 3 Ton Air Conditioner. The customer's upgraded to Carrier systems. I cycled and monitored the systems and they are both operational at this time.

Dakota J.

Dakota J. Job Checkin

I installed a Carrier 13 SEER 3 Ton Air Conditioner and a Carrier 80% 90,000 BTU Gas Furnace. I cycled and monitored the systems and they are both operational at this time.

I installed a Carrier 13 SEER 3 Ton Air Conditioner and a Carrier 80% 90,000 BTU Gas Furnace. I cycled and monitored the systems and they are both operational at this time.

Hassan H.

Hassan H. Job Checkin

I gave an estimate to install a Five Star 80% 45,000 BTU Gas Furnace 3T 14" and a Five Star 13 SEER 2 Ton Air Conditioner. I included in the estimate is a 1 year free service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Trane AC unit. I found the cap and wiring was bad. I replaced both the cap and wiring and ran the system. It ran with no further issues and it is operational at this time.

I completed a diagnostic on a Trane AC unit. I found the cap and wiring was bad. I replaced both the cap and wiring and ran the system. It ran with no further issues and it is operational at this time.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on a Maytag air conditioning unit. I found the the cap blown and a clogged filter. I replaced the cap and removed the filter. The customer did not want us to fix. The system is operational at this time.

I completed a diagnostic on a Maytag air conditioning unit. I found the the cap blown and a clogged filter. I replaced the cap and removed the filter. The customer did not want us to fix. The system is operational at this time.

Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on an Armstrong air conditioning unit. I found the filter to be clogged, so I replaced that. I also found the contactor pitted. The blower does not sound good when starting it up. I recommended a unit replacement do to the issues. At the time of departure, the system is operational.

I completed a diagnostic on an Armstrong air conditioning unit. I found the filter to be clogged, so I replaced that. I also found the contactor pitted. The blower does not sound good when starting it up. I recommended a unit replacement do to the issues. At the time of departure, the system is operational.

Hassan H.

Hassan H. Job Checkin

I gave an estimate on a Carrier 13 SEER 3 Ton Air Conditioner. Included with the installation is a free 1 year service maintenance agreement.


Hassan H.

Hassan H. Job Checkin

I installed a Carrier 13 SEER 2.5 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time.


Hassan H.

Hassan H. Job Checkin

I completed a diagnostic on an AC unit. I determined that Condenser coil is in very bad shape and evap coil is completely plugged. I gave the customer options and sent a replacement quote

I completed a diagnostic on an AC unit. I determined that Condenser coil is in very bad shape and evap coil is completely plugged. I gave the customer options and sent a replacement quote

Hassan H.

Hassan H. Job Checkin

I went to customers home to perform a diagnostic on a Trane air conditioning unit, but I was unable to provide service.


Hassan H.

Hassan H. Job Checkin

I performed a diagnostic on a Bryant AC and determined that the Tstat wiring was incorrect. I was not charging the customer. Cycled both AC and heat, all good.

I performed a diagnostic on a Bryant AC and determined that the Tstat wiring was incorrect. I was not charging the customer. Cycled both AC and heat, all good.

Hassan H.

Hassan H. Job Checkin

I went to customers home to perform a diagnostic, but client was more interested in just replacing furnace then diagnostic, but diagnosed a failed blower motor. Waived diagnostic and scheduled furnace replacement


Hassan H.

Hassan H. Job Checkin

I completed diagnostics and found it 58F coming out of registers upstairs. I added a 0.5lb of 410A. The refrigerant levels at 90F saturation temp:116/292 9SC. The system reached desired temp and shut off like it should. The system is operational upon departure.


Hassan H.

Hassan H. Job Checkin

I performed a diagnostic on a Bryant air conditioner. I found that the system was extremely low on refrigerant due to a leak. I went over the options with the customer and they decided to replace the system.

I performed a diagnostic on a Bryant air conditioner.  I found that the system was extremely low on refrigerant due to a leak. I went over the options with the customer and they decided to replace the system.