Insepection of heat pump

knowledgeable and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great set

It was great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Kind and knowledgeable and fast service

A good experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for loveland, oh

Gage R.

Gage R. Job Checkin

I installed a Five Star 13 SEER 3 Ton Air Conditioner. The customer has upgraded the unit to Carrier. I cycled and monitored the system and it is operational at this time.

I installed a Five Star 13 SEER 3 Ton Air Conditioner. The customer has upgraded the unit to Carrier. I cycled and monitored the system and it is operational at this time.

Dakota J.

Dakota J. Job Checkin

I went to customers home to replace an out of warranty part. I installed new stat and system was blowing fuses. After looking at everything found that this stat is DC volts only and system is AC volts. Put old stat back on and system is operational. Customer is gonna buy a Nest stat and pay us to come back out and install it and rewire it at the furnace.


Gage R.

Gage R. Job Checkin

I installed a Five Star 96% Gas Furnace (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Five Star 16 SEER Air Conditioner. Cycled and monitored the system. Operating normally at this time.


Dakota J.

Dakota J. Job Checkin

I went to the customer's home to install a Five Star 96% 60,000 BTU Gas Furnace, a Five Star 16 SEER 2.5 Ton Air Conditioner, Aprilaire 500 Humidifier, and a iWave-R Air Purifier. Everything was fully operational when I left.


Janaea J.

Janaea J. Job Checkin

I performed a tune up and safety check on a Westinghouse heat pump. I found that the unit was having intermittent TXV issues. I was able to get the pressures stabilized. I also found that the compressor-motor surge capacitor needed replaced so I replaced it.

I performed a tune up and safety check on a Westinghouse heat pump. I found that the unit was having intermittent TXV issues. I was able to get the pressures stabilized. I also found that the compressor-motor surge capacitor needed replaced so I replaced it.

Josh A.

Josh A. Job Checkin

Dispatched to customer's home to diagnose no heat issue with furnace. Customer stated system stopped heating overnight System is a dual fuel heat-pump & gas furnace. Upon arrival I turned unit on at thermostat - Only blower would come on. Installed new thermostat and wired it for heat using gas furnace only. Issue resolved.

Dispatched to customer's home to diagnose no heat issue with furnace. 
Customer stated system stopped heating overnight
System is a dual fuel heat-pump & gas furnace.
Upon arrival I turned unit on at thermostat - Only blower would come on. Installed new thermostat and wired it for heat using gas furnace only. Issue resolved.

Josh A.

Josh A. Job Checkin

Installation of a Carrier 96% 80,000 BTU Gas Furnace.

Installation of a Carrier 96% 80,000 BTU Gas Furnace.

Tara L.

Tara L. Job Checkin

During a tune up on a 2013 Westinghouse furnace, I pulled and cleaned the flame sensor. The blower capacitor is reading out of specifications so I replaced. Everything is operating as intended at time of departure.

During a tune up on a 2013 Westinghouse furnace, I pulled and cleaned the flame sensor. The blower capacitor is reading out of specifications so I replaced. Everything is operating as intended at time of departure.

Bella M.

Bella M. Job Checkin

I completed a diagnostic on a Lennox gas furnace. Determined that this unit does not have a condensate trap. Unit has been draining directly onto the floor for awhile. I will need to get pricing for the condensate trap and then order once repairs have been authorized.

I completed a diagnostic on a Lennox gas furnace.  Determined that this unit does not have a condensate trap.  Unit has been draining directly onto the floor for  awhile.  I will need to get pricing for the condensate trap and then order once repairs have been authorized.

Dawn M.

Dawn M. Job Checkin

I replaced a humidifier pad and the inducer motor. System is operational upon departure.

I replaced a humidifier pad and the inducer motor. System is operational upon departure.

Bella M.

Bella M. Job Checkin

I found that a bearing going bad within the motor is causing loud noise. We will be back to replace 90% OEM Inducer Motor. Furnace is operational at time of departure.

I found that a bearing going bad within the motor is causing loud noise. We will be back to replace 90% OEM Inducer Motor. Furnace is operational at time of departure.

Sarah F.

Sarah F. Job Checkin

The clients unit caught on fire. Will need a heat kit, circuit board and a transformer. Client will also need to have new electric and breakers added at box. Client thinking about replacing unit.

The clients unit caught on fire. Will need a heat kit, circuit board and a transformer. Client will also need to have new electric and breakers added at box. Client thinking about replacing unit.

Josh A.

Josh A. Job Checkin

I provided an estimate on a 5 Star Multi-Speed X-13 2 Ton Electric Furnace / "Slant" Coil and a 5 Star 14 SEER 2 Ton Heat Pump


Joe G.

Joe G. Job Checkin

I installed a new Five Star Multi-Speed 2 Ton Electric Furnace and a new Five Star 15 SEER 2 Ton Heat Pump

I installed a new Five Star Multi-Speed 2 Ton Electric Furnace  and a new Five Star 15 SEER 2 Ton Heat Pump

Joe G.

Joe G. Job Checkin

I installed a new Five Star Multi-Speed 2 Ton Electric Furnace and a new Carrier 16 SEER 1.5 Ton Air Conditioner.

I installed a new  Five Star Multi-Speed 2 Ton Electric Furnace and a new Carrier 16 SEER 1.5 Ton Air Conditioner.