He 100 percent knew what he was doing! I wish more technicians would be like the gentleman the came to diagnosis our ac system!
Joshua, my service technician, helped me weigh my options honestly and helped me find the best deal possible.
Our A/C broke. They were at our house within two hours of the call. They had it patched up in two hours after arriving. Repair staff were helpful and informative. They installed our new unit only two days later, and again, within two hours. Josh Adkins, Aaron Kinman, and JP Long did great work.
I performed a diagnostic on a 2012 Goodman gas furnace that was producing a gas smell. Using soap bubbles I sprayed the area in question and was unable to detect any leaks. I then used a digital leak detector and got the same results. I replaced the knuckle just to be on the safe side.
I installed a Five Star 96% 80,000 BTU Gas Furnace 4T 17". With this install comes a scheduled maintenance agreement lasting a year.
I performed a diagnostic on a 2005 Trane gas furnace that is producing an abnormal sound. The noise the customer is referring to are the bearings in the blower motor going out. The customer opted to have the furnace replaced.
I performed a diagnostic on a 2005 Trane gas furnace that is producing an abnormal sound. The noise the customer is referring to are the bearings in the blower motor going out. The customer opted to have the furnace replaced.
During a tune up on a Bryant electric furnace, I found some of the thermostat wires were not connected. I connected them properly and the system was working as it should upon departure.
Upon arrival I found the inducer motor kicking on for 2 seconds and then shutting back off and trying again. I checked the voltage with the inducer motor plugged in and it would lose voltage from board right after coming on. I checked the voltage while the inducer motor was not plugged in and board would send constant voltage to inducer motor. Inducer motor seems like it’s back feeding electricity to board.
I installed Five Star 96% 60,000 BTU Gas Furnace 3.5T 17" with this includes Scheduled Maintenance Agreement Price includes: 1-Cooling Tune-Up 1-Heating Tune-Up Customer to receive PRIORITY SERVICE 50% Off Normal, After Hours or Holiday Diagnostic 10% Off All repairs 10% Off Any Indoor Air Quality Equipment
I found the blower motor had seized. I gave the customer a quote on replacing the system.
Installed a Five Star 80% 70,000 BTU Gas Furnace.
Used aluminum tape to stop The metal from rubbing and the noise went away this is a Carrier Gas Furnace 96% Variable Speed Two-Stage 80,000 BTU.
I am Performing our Five Star Tune-Up & Safety Check on a 2020 Electric Carrier Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
Removed gas valve and installed new valve. Restarted system and checked for leaks. Set pressures. As of departure the system has been running for 20 mins with no issues
Customer recently purchased the house advised had no trouble with ac, however when they went to turn the heat on there was no heat Customer further advise that when they would switch the fan from auto to on the fan will come on Checked thermostat wiring on the furnace board and found no problems checked wiring at the thermostat found it incorrectly wired. Rewired thermostat and restarted system. System is operational and heating the house cycled system on and off several times before departing
I provided an estimate for a new Carrier 80% 70,000 BTU Gas Furnace a long with a new Carrier 16 SEER 2.5 Ton Air Conditioner