7077 Beach Dr SW
Ocean Isle Beach, NC 28469
9107542200

Local Reviews
for ocean isle beach, nc

Rated 4.9 out of 5 stars based on 444 customer reviews

Jackie

A+ has serviced our cottage for 12+ years. They’re always striving to get to us as soon as possible when called and send professional, personable techs to fix the problem. We recommend them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Air duct damper

The technician Lionel was very professional and knowledgeable. He took time to explain how the dual zone system works. Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Kevin

Kevin was very respectful to since I was here by myself. I appreciate the the way he talked to me and informed me what he did. You should really value him as a great employee. The next time I have a problem I will ask for Kevin to come out and check my unit

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Wonderful company! Very trustworthy and friendly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service/Joe was very respectful to me and I appreciate it

so glad he was able to help us

  • Overall Experience
  • Quality
  • Price
  • Convenience

AC up & running

Knowledgeable, pleasant, & efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Lamaeca

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service call

Lionel was very professional, and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional, personal and very meticulous

Great people

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ben

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for ocean isle beach, nc

Christopher T.

Christopher T. Job Checkin

Found that the wiring harness for the compressor was shorted to the suction line refrigerant receiver also the outdoor coil is corroded really bad and needs to be replaced IAQ coming out to price new system


Joe W.

Joe W. Job Checkin

Demand call on a 2016 Goodman heat pump split system. When I walked up to the unit I look down inside of it and saw the true suction had rubbed against the suction line. This has created a leak ,repaired leak ,weighed in charge of 10 pounds 410 a. No further action is needed system is operating normally at this time. Unit is under warranty.customer is paying with 2 checks from 2 accounts


Joe W.

Joe W. Job Checkin

Call back on a 2009 weather king outdoor unit and a 2005 Goodman air handler inside. Found system completely out of Freon it holds r22. System is in very bad shape due to heavy corrosion. Model and serial numbers are correct in the system. Spoke with homeowner about the issue they have asked to speak to a comfort adviser about replacement. Comfort adviser has been notified.


Joe W.

Joe W. Job Checkin

Call back on a 2015 or 16 Lennox heat pump split system. Found system low on Freon trace the leak back to the evaporator coil there is a video in Files showing the leak. Need to order the evaporator coil system is under warranty.


Joe W.

Joe W. Job Checkin

Demand call on a 2013 Goodman heat pump split system. Both units are labeled 2013. Found the breaker tripped reset breaker system came on and it’s running OK. There are some condition issues with the upstairs unit which if you’re looking at the platform is the one to the right. The condenser coil is in pretty bad shape this will be a problem down the road . I don’t see any indicators at this time of why the breaker would be tripped. Instructed customer to keep an eye on it.


Michael P.

Michael P. Job Checkin

John to meet inspector during final inspection


Christopher T.

Christopher T. Job Checkin

Found the condensation line on both systems or clog SS2 switch shut the system down on the upstairs system and the pan switch shut down the downstairs system both are up and running at this time.


Auston .

Auston . Job Checkin

Checked all electrical numbers and Freon pressure cleared drain line system is operating properly at this time


Christopher T.

Christopher T. Job Checkin

Turn humidifier down so it would run waiting on the Material to come in to move the ductwork coming from the dehumidifier.


Chris H.

Chris H. Job Checkin

2018 Ruud Downstairs system not cooling. Upon arrival temp inside home was 70 degrees. Set tstat to 68 to start system and check. Pressures are good. Set upstairs tstat to same temp as downstairs system to help the downstairs temp. Unit is working at this time. Outside temp is 101.


Auston .

Auston . Job Checkin

Checked all electrical numbers and Freon pressure cleared drain line system is operating properly at this time


Kevin M.

Kevin M. Job Checkin

Found there to be a clogged drain line as well as the pitch being off on the primary pan. Customer also wanted me to install a UV light. -notes


Joe W.

Joe W. Job Checkin

Performed prepaid maintenance on a 2011 carrier heat pump split system. During inspection found refrigerant levels within spec ,amp draw’s are reading OK ,airflow is good. I did find in the air handler ,the evaporator coil is in pretty bad shape due to heavy corrosion ,pictures are enclosed. Unit is under warranty but will be out very soon. Customer is going to think about the cost of the coil and will let us know what they would like to do. Recommending replacement due to age condition and overall efficiency not to mention future repairs .


Chris H.

Chris H. Job Checkin

2013 Goodman System was blowing air but not cooling. Checked system and found return filter and media filter were being used. Both filters were dirty and in need of replacement. The media filter had a date of 2013 on it. Explained to customer that they should only be using one or he other as this puts strain on the system. Replaced customer provided return filter. Checked pressures and they are good. Checked capacitor. Checked drain line. System is working at this time. Temp inside is 80, down from 82 after running for 20-30 minutes


Kevin M.

Kevin M. Job Checkin

Condensate pump