7077 Beach Dr SW
Ocean Isle Beach, NC 28469
9107542200

Local Reviews

Rated 4.8 out of 5 stars based on 166 customer reviews

Professional and knowledgeable technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service

Great service in pouring rain

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Noah is a wonderful representative. Kind, knowledgeable, clean cut

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

reliable service, office and field.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Estimate for lights installed

Excellent professionalism and prompt with updates on when they will be arriving. Also sent me a text of his picture for security. Very respectful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

semi annual examination

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Robert showed up on time and completed the work in a resonable time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from A+ Heating & Cooling- Electrical:

Glad to hear you received Great services!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Robert S.

Robert S. Job Checkin

The condensation pump was unplugged from the 120 outlet


A+ T.

A+ T. Job Checkin

Preformed service call on 1988 Coleman furnace. Furnace has leak in system and homeowner would like pricing on new system


Robert S.

Robert S. Job Checkin

The condenser fan wasn’t starting due to a bad duel capacitor. I replaced the capacitor and checked the operation and pressures.


A+ T.

A+ T. Job Checkin

Preformed service call on 2019 Goodman system I reconfigured thermostat and system is working properly at this time


A+ T.

A+ T. Job Checkin

Preformed service call on 2014 system found faulty ambient sensor we will need to order a new sensor


A+ T.

A+ T. Job Checkin

Replaced whip to condenser, installed romex connector, sealed condenser disconnect, installed whip to air handler, and verified proper breaker sizes and voltage. Material list in notes.


A+ T.

A+ T. Job Checkin

Preformed service call on 2017 ruud system found high pressure switch had tripped I reset and system is working properly at this time


A+ T.

A+ T. Job Checkin

Preformed service call on carrier system and found the condenser has been corroded away client would like bid on new system


Robert S.

Robert S. Job Checkin

I performed the seasonal maintenance. All amps,volts, and capacitors are withen specs. The operating pressures are slightly low. The system is 17 years old and not worth investing a lot of money in repairs.


A+ T.

A+ T. Job Checkin

Diagnostic call on a 9 year old split heat pump system. Client wanted refrigerant put in. Checked over air handler and condenser first to make sure there were no air restrictions. Added 2 lbs of r22 refrigerant. System superheat reads within manufacturing specs at this time. Found that the leak is coming off the evaporator coil. Someone had put a dye in here. There is oil on the evaporator coil and dye. Client did not want repair or replacement options at this time. Recommend a service agreement for the system. No guarantees on refrigerant. System is undersized for the home. The load calculation calls for a 30,000 btu system not 24,000 which is what’s here. Client says that it doesn’t cool properly in the late afternoons in the summer. Entered all information in the system, Put sticker on unit and gave client a refrigerator magnet.


A+ T.

A+ T. Job Checkin

Replaced 12-15ft of 12” flex duct.


A+ T.

A+ T. Job Checkin

Train josh on attaching flex pipe, Installed flex pipe & sealed


A+ T.

A+ T. Job Checkin

Preformed system maintenance on 2004 tempstar system I checked wire connections, amp draws, capacitors, duct work, air filter, refridgerant levels, coils, and drains. I cleaned coils and drains system is working properly at this time


A+ T.

A+ T. Job Checkin

Check the dehumidifier after re-wiring and trying to get the dehumidifier to run come to find out ecobee thermostat will not run the humidification or allow you to set it when ahead and set dehumidifier to standalone at 55% humidity installed overflow switch and drain pan underneath dehumidifier unit is working OK at this time Call back no charge for service


Melody S.

Melody S. Job Checkin

Finished install the rest of the outside lights.