Going the Extra Mile

System down again on Sunday Last time a month ago. Got service on Sunday but was unable to fix. They drove to Wilmington and got a part for us. Installed Monday afternoon and we were cool again. Wife is bed ridden with dementia. Thanks ladies and men of A-1

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very polite, extra thorough.


Response from A+ Heating & Cooling- Electrical:

Thank you, Kathleen, our technicians like to work diligently and check all ends before jumping to conclusions to make sure we get to the bottom of the issue, so you can enjoy the air conditioning.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very helpful


Response from A+ Heating & Cooling- Electrical:

Hi Kathleen, thank you for sharing your experience with Swift Services. Here at Swift, we take the time to explain what we are doing while performing services. HVAC units are some of the most complex systems in our homes, so it is important that our customers understand what and why we are doing

  • Overall Experience
  • Quality
  • Price
  • Convenience

Raining so outside unit not serviced


Response from A+ Heating & Cooling- Electrical:

Hi Kathleen, we would love an opportunity to discuss your recent experience and find out what we could do in the future to make your next visit a 5-star one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied customer

Very thorough inspection and maintenance service. A+ lives up to their name.


Response from A+ Heating & Cooling- Electrical:

Thank you, Walter, for your 5-star rating.

  • Overall Experience
  • Quality
  • Price
  • Convenience

One week and $350 later the system is shutdown

You people are terrible. And Trane AC sucks


Response from A+ Heating & Cooling- Electrical:

Hi Mike, I can assure you we are some of the best out there! I am sorry though to hear your system is acting up again, with older systems it is not that uncommon that multiple issues are occurring at the same time. Usually, this can not be detected until one problem is fixed. I let the manager know your concerns and he will be reaching out to you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Excellent work, good clean up afterward


Response from A+ Heating & Cooling- Electrical:

Thank you for sharing your recent 5-star HVAC experience with us!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Brian worked all day, cleaned up afterward. Great job!


Response from A+ Heating & Cooling- Electrical:

Thank you for sharing your recent 5-star HVAC experience with us!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from A+ Heating & Cooling- Electrical:

Thank You, please refer us to your Neighbors, friends, and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Here we go again

Had this unit for a little over 1.5 years. Every time it gets warm this unit does not cool. Apparently the same problem as last year - cracked nut that allows all the coolant to escape at the wall unit. Could not fix has to come back with a proper sized nut.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for saint james, nc

Lionel L.

Lionel L. Job Checkin

Went through a hard reset system is working properly at this time


Lionel L.

Lionel L. Job Checkin

2015 Lennox system during inspection found capacitor for compressor weak added hard start, reset change filter reminders. system is working properly at this time


Kevin M.

Kevin M. Job Checkin

Performed routine maintenance on 2 Goodman systems


Joe W.

Joe W. Job Checkin

Replaced warranty stepper motor on a 2016 train fully communicating heat pump split system. System is operating normally at this time


Joe W.

Joe W. Job Checkin

Call back on a 2016 train heat pump split system. This is a fully communicating system. Found the EEV not responding went into the attic jumped aboard a few times to get it to open and close the valve is now operating. I think the stepper motor needs to be replaced once the motor is replaced then we can do a full inspection to make sure there are no other issues. Office will have to give price for the warranty step motor I will put a return for parts in.


Joe W.

Joe W. Job Checkin

Performed routine maintenance on a 2013 carrier heat pump split system for the main area and a 1998 Goodman heat pump split system for the mini area. The carrier is starting to show signs of its age though it is running properly at this time. The evaporator coil is starting to get chewed up from corrosion as well as the secondary pan underneath of the unit. The 1998 is working it has had a repair to the accumulator recently. The company that did the repair used 407C refrigerant which I educated the customer on. The evaporator coil has heavy corrosion on it as well as the inside insulation is starting to come apart. Both systems have 22 year old duct board trunk lines. Once customer is ready to replace the systems I recommend having both of them replaced along with the equipment. Please schedule customer for a early November maintenance to get his heat checked out. I’m recommending replacement on the 1998 Goodman system. Pictures are enclosed of some of the damage.


Scott S.

Scott S. Job Checkin

System was found to be having trouble with the electronic expansion valve. Upon further investigation it was discovered that the suction line temperature thermistor had become uninsulated, providing the computer with improper data. No further issues were presently detected with the equipment.


Zech M.

Zech M. Job Checkin

2x 2015 Lennox heat pump systems. Checked the voltage, amp draw, connections, pressures, capacitors, contactors, ensured all connections throughout were properly tightened down and in proper place, cleaned coils, cleaned drain lines, tested float switches, resecured thermostat wires inside of air handler, these two systems are working properly at this time.


Michael P.

Michael P. Job Checkin

Changed correct breaker. Checked install


Kenneth b.

Kenneth b. Job Checkin

Changed breaker for AC Checked all wires and connections Checked disconnect boxes


Lionel L.

Lionel L. Job Checkin

2/2005 Goodman systems R22 clean and flushed condensate drain to remove clog made sure both condensate pumps were working properly Freon in both units is a little low Will continue to monitor pressures during maintenance visits


Arnold K.

Arnold K. Job Checkin

One system maintenance 2019, customer would like adjustable register installed in room five there is not one there now, gets to cold in that room.


Zech M.

Zech M. Job Checkin

2015 carrier heat pump system. Checked voltage, amp draw, connections, pressures, capacitors, contactor, rewired red inside of air handler that was causing a short and put a new fuse on the wire as well. Installed new pan strip, and uv light kit, also tested float switches, and cleared drain lines. Cleaned coils and ensured all connections throughout were properly tightened down. This system is working properly at this time.


Zech M.

Zech M. Job Checkin

2018 trane heat pump system. Checked voltage, amp draw, connections, pressures, capacitors, contactors, float switches, cleaned drain line, coils, and resecured wires inside of outdoor unit. Replaced filter on fresh air return, ensured all zones operated properly. This system is working properly at this time no issues were found.


Scott S.

Scott S. Job Checkin

Found bad capacitor replaced tested ok, also checked pressures ok, one system 2y old.