Have any feedback for us? We'd love to hear it! Call us at (405) 888-5253 and let us know how we are doing.
I will be referring Above & Beyond to other business' and friends
Kirk was able to show up earlier than expected. He diagnosed he problem as a separated thermostat wire very quickly. He was able to reconnect and solve the major issue with unit for a very reasonable price.
This company is one of the few I've dealt with that truly cares about its customers. Combine that with the cutting-edge expertise of the technicians, and you've got service that truly is Above & Beyond.
Hands down in Guthrie!! Above and Beyond offers Excellent customer service, pricing and follow through on their promise. They are responsive and even kept in touch via text with a tracking link (kinda like Uber has) as Jesse was in route. Even sent a picture of him so we wouldn’t open the door to a stranger. Wow!! Is all I can say. I’m impressed and even though another company installed our new HVAC system in 2017 we will use Above and Beyond HVAC for our service and maintenance needs.
Response from Above & Beyond Heating & Cooling:
Thank you so much for your review! We work hard to provide a superior level of customer service and professionalism. We look forward to serving you for years to come!
They really went above and beyond. I felt like their heart was really in it because they did everything they could in a timely manner to make sure we wouldn't have to spend any more time in our extremely hot house than we needed to. They knew EXACTLY what was wrong with our AC unit and it took no time at all for them to figure it out. The service was impeccable. I will never go to anyone else!! Recommend to all!!
114 harvest Bad 60amp breaker Breaker replaced and system is operating
Bad compressor Tries to come on but is mechanically locked 2ton condenser or new compressor is needed
102 winter wheat Bad 60amp breaker New breaker installed and system is cooling
Upon arrival system running fan only. Checked filter clean. Hooked I manifold up system running in cooling temp split good sub cooling 13 degrees superheat 16 degrees 410 a system ran for 30 minutes and everything is good.
Check system for capacity issue noticed by inspector. Verify system performance with iManifold system. Home heated & cooled by five ton heat pump with air handler. Unit has an indoor TXV for cooling and an outdoor orifice for in heating mode. Set thermostat to start at 70 while hooking iManifold to system and placing probes in ducts. Cleaned outdoor unit and checked indoor air handler blower and coil before starting tests. System achieved a 19.7 degree temperature split after stabilizing. Unit is running efficiently. No issues discovered with unit.
114 harvest Bad 40/5 capacitor Condenser was really dirty so I washed it out System on and cooling Return temp 76 Supply temp 57
Trouble shoot unit condensate drain clogged. Pumped about 120 lbs of nitrogen to remove debris.
Inside panel that covers coil on American standard coils not installed correctly causing airflow issue and not allowing coil to get cool enough
110 silent way Bad blower motor Ordered part and will return to install it later today Motor installed and system is cooling
108 winter wheat Bad 30 amp breaker inside of air handler Breaker installed and system is cooling
113 silent way Bad blower motor Motor is under warranty Motor installed and home is cooling
209 silent way Mai tender guy pulled water out of plenum earlier today and system was frozen over System is now cooling as it was before System refrigerant charge is contaminated will cause damage to txt or compressor
201 winter wheat Bad 60amps breaker Breaker replaced and system is cooling
2 wire broken at condenser Thermostat not sending power to turn ac on Once jumpers the wires I found that compressor is locked out Customer needs new system Gave quotes on system replacement
Condenser really dirty so I washed it Filter new but old filter was changed a couple days ago and was really dirty system was frozen when filter was changed and just stayed frozen til system was turned off and thawed out Added 1lb 410a