17300 N. May Ave, Ste A
Edmond, OK 73012
405 657-2484

Have any feedback for us? We'd love to hear it! Call us at (405) 888-5253 and let us know how we are doing.

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 297 customer reviews

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service recovery

Had a new motor fail and they came out replaced promptly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt and professional service

They got a crew out the same day to fix a complicated problem.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very responsive

The guys at Above and beyond air-conditioning do a great job in a timely manner

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Jason called, showed up on time, did a great inspection on my AC, made recommendations on preventative maintenance. Went above and beyond by testing the breaker box to make sure the AC unit wasn’t drawing to large of a load.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and price.

Jason and his employees are very knowledgeable and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and very quick to get your problem fixed

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Jason B.

Jason B. Job Checkin

AC not cooling. Filter was dirty. Cleaned filter and unit is running in accordance with manufacturers specifications.


Jason B.

Jason B. Job Checkin

Charge system with R-22 Freon


Jason B.

Jason B. Job Checkin

AC was frozen. Unit thawed and took pressure checks of system. Unit was cooling but slightly low on Freon. Added 1.5 lbs of R-410A.


Jason B.

Jason B. Job Checkin

Condenser fan motor bearings bad. Replaced motor and unit not making noise,


Jason B.

Jason B. Job Checkin

AC not cooling. Found leak in coil piping. System is R-22 and is empty.


Jason B.

Jason B. Job Checkin

AC on north side of the house not cooling properly. Found TXV was not metering refrigerant. Replaced metering device, evacuated system and home is cooling. Blew out drain and insured system is running per manufacturer’s specifications.


Kressy D.

Kressy D. Job Checkin

Inside panel that covers coil on American standard coils not installed correctly causing airflow issue and not allowing coil to get cool enough


Kressy D.

Kressy D. Job Checkin

110 silent way Bad blower motor Ordered part and will return to install it later today Motor installed and system is cooling


Kressy D.

Kressy D. Job Checkin

Low on 410a Has leaking coil Elected not to do anything today Fixed electrical whip at furnace was cut and was causing issues with power to furnace


Kressy D.

Kressy D. Job Checkin

Bad 30/5 capacitor Replaced capacitor and system is cooling Customer is to have her husband wash condensers Customer wanted quotes on replacing both systems


Kressy D.

Kressy D. Job Checkin

System out of refrigerant Found leak in coil Gave customer quotes and replacement


Kressy D.

Kressy D. Job Checkin

Bad 40/5 capacitor


Kressy D.

Kressy D. Job Checkin

45/10 capacitor reading 32.7/8.6 out of tolerance but still working I recommend replacing Fan amps 1.3 max per data plate is 1.7 Compressor amps 20.58 max per data plate is 20.3 Washed condenser and compressor amps stayed high Checked charge and temp split picture on file Compressor running hot so refrigerant charge can not be determined with certainty System is cooling but not very efficiently System is 25yrs old and is cooling the best it can


Kressy D.

Kressy D. Job Checkin

50/5 capacitor reading 48.8/4.78 Fan motor amps 1.7 max per data plate is 1.9 Compressor amps 23.7 max per data plate is 26.3 Condenser is dirty needs washed Filters are really dirty - customer changed filters while I was there and said they would wash condenser System cooling well Compressor and fan motor running high amps, they are 12yrs old and just working really hard I wouldn’t be surprised if one of them went out Out later that day Customer washed condenser and now system is not cooling anymore so they called me back out Condenser fan motor locked up causing compressor to lockout on overload Will return tomorrow to install fan motor 9-11-19 Returned and installed new motor and system is cooling Compressor is pulling really high amps 22.89 and max is 26.3 compressor is on its last leg


Kressy D.

Kressy D. Job Checkin

108 winter wheat Bad 30 amp breaker inside of air handler Breaker installed and system is cooling