Job Locations
for the village, ok

Jason B.

Jason B. Job Checkin

AC not working. Unit freezing up. Unit was missing filter. Discovered unit was low on R-22 Freon. Added 6lbs of R-22 to unit. AC is working and cooling home.


Jesse E.

Jesse E. Job Checkin

Let owner know needs to have condensate drain and overflow switch installed price $372.47 plus $89.99 for service call. If old condensate pump does not work $608.75 for new one.


Jesse E.

Jesse E. Job Checkin

New furnace, coil, condenser, and thermostat comes with 10yr parts and 10yr labor warranty New plenum to match coil and reattach ducts 4 Also add in electrical plug so unit isn’t hard wired Filter rack to match bottom of furnace Condenser pad and redo 2wire at condenser Added 300 dollars for flex price


Kressy D.

Kressy D. Job Checkin

Upon arrival tenant stated that system was frozen up for multiple days, tenant changed filter and system started cooling again I added new 24x14 filter and noticed that system is low on r22, I checked around condenser and line set for leaks and didn’t find any, I then checked around line set in attic and coil and I found leak in coil video on file Coil needs replaced but with the age of the complete system I would recommend replacing everything so that you can get everything into a warranty so that out can live stress free for awhile Equipment is 17 1/2 wide and opening is 20 1/2 wide Will have to take trim down from opening to get old equipment out and new equipment in


Jason B.

Jason B. Job Checkin

Ac duct broken under home. No access under home to affected area.


Kressy D.

Kressy D. Job Checkin

Crawl space too small we don’t have a person to fit under the house to fix issue


Kressy D.

Kressy D. Job Checkin

Installed new coil and txv Adjusted charge System is cooling very well


Kressy D.

Kressy D. Job Checkin

Found leak in coil


Kressy D.

Kressy D. Job Checkin

Installed surge protector Spring tune up System low on r22 1-3lbs customer wants to return to preform a leak search


Jason B.

Jason B. Job Checkin

Estimate for moving heating and cooling from floor boots to attic.


Jason B.

Jason B. Job Checkin

AC not working on west side of home. Found capacitor out of tolerance. Fan motor would run until it gets hot and shuts off. Cleaned and serviced both ac units. Removed covers and cleaned with coil cleaner. Replacement of outdoor fan motor


Jesse E.

Jesse E. Job Checkin

Leak found on indoor coil on trunk line. Tech pulled Freon into condenser and valves off. Then Tech welded line, charged with nitrogen checked leak again, found no more leak. Pulled vacuum and recharged system. Added 3lbs. To systems charge.


Jason B.

Jason B. Job Checkin

Bad control board Installed new control board and roll out switch System heating when I left


Jesse E.

Jesse E. Job Checkin

Bad control board Installed new control board and roll out switch System heating when I left


Jason B.

Jason B. Job Checkin

OG&E Commercial Tune-Up