577 Sterling Drive
Richardson, TX 75081
972-591-0199

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 381 customer reviews

Great Service!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best Service Ever

Jason was the best tech I have ever worked with. He didn’t try to sell us something while doing our maintenance. That is what all other try and do. He was very knowledgeable and explained some things we could do to help cool in the summer and heat in the winter.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service experience

Part of our maintenance contract. Polite, knowledgeable and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great quick service

He was very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Well done

  • Overall Experience
  • Quality
  • Price
  • Convenience

All is good

Professional, timely and helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Did the needed repairs quickly and gave welcomed insight on present condition of the vent system

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Good Service

We have been an AC PRO customer for a long time. Joel was very knowledgeable, professional and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

👍

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

I feel Joel did a fine job of inspection and maintenance of my heating system. He didn't rush in and out, But took time to do a through examination of the system and gave a good report

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Jason D.

Jason D. Job Checkin

System components checked. Airflow, attic insulation and registers are an issue because air isn't going where it should rooms don't stay the right temp without proper insulation.


Joel S.

Joel S. Job Checkin

Heating performance tune up times one system. Inspect blower, evaporator. Test all safety features on air handler. Check amp draw on 10 KW heat strips. 21.04 amps each. Test thermostat for proper operations. Check outdoor unit. Test run capacitor and contactor. Both coils are clean at this time. Changed out filter client Supply. System operating at manufacturer specs at this time.


Jason D.

Jason D. Job Checkin

Blower, ignitor, flame sensors all checked. Airflow condensate drain line pitch and registers are alla concern. Thermostat should be upgraded and attic should be installed given the thermostat placement. Can confirm heat is running at this time


Joel S.

Joel S. Job Checkin

Heat performance tune up times two systems. Inspect blowers, evaporators and ductwork. Test all safety features High limits and roll out. Check heat exchanger for cracks found none. No carbon monoxide or gas leak detected in home. Tightened all wire connections. Tested thermostats for proper operations. Systems operating at manufacturer specs at this time.


Cole K.

Cole K. Job Checkin

Both systems working properly in heat mode at this time. The upstairs system is 17 years old and is showing 6ppm of carbon monoxide. I would recommend replacing this system. I would also recommend adding surge protection to the downstairs system.


Jason D.

Jason D. Job Checkin

Arrived to find system shutting down due to bad flame sensor and dirty filter. Filte is an outdated electronic one with pre-filter that is an odd size so ill send some info and an estimate for possible replacements. Flame sensor was changed and all other components were checked. System is a zoned carrier with infinity touch thermostat which makes it difficult to change blower speed but high static due to lack of bypass is also a possible issue. Can confirm heat is running at this time but we need to monitor due to airflow issues.


Cole K.

Cole K. Job Checkin

Main system has burnt connections to control board. When system calls for second stage he blower changes speed but the gas valve doesn’t go into hi. Also the blower motor is pulling high amps and showing signs of failure. Most of the duct work is in pretty bad shape and duct board mixing boxes are bleeding air into attic space attracting rodents and making the system inefficient. I would recommend replacing the AC side of all of these systems since they are past their life expectancy and are R22 refrigerant, and I would recommend replacing all ductwork for a more efficient system.


Joel S.

Joel S. Job Checkin

Heating performance tune up times one system. Change out filter client supplied. Inspect blower, evaporator and ductwork. Test all safety features High limits and roll outs. Tightened all wire connections. Check gas pressure. System has 3.5 in of water column. Check heat exchanger for cracks found none. No carbon monoxide or gas leak detected in home. Test thermostat for proper operations. System operating at manufacturer specs at this time.


Jason D.

Jason D. Job Checkin

CLEANED THE FLAME SENSOR AND INSPECTED HEAT EXCHANGERS - CHECKED FOR CO - CHECKED ALL THE SAFETY SWITCHES AND TIGHTENED ALL THE ELECTRICAL CONNECTIONS - THE FILTER IS STILL IN GOOD SHAPE - THE SYSTEM IS WORKING PROPERLY ON HEAT MODE AT THIS MOMENT - TECH REC: MAINTENANCE RENEWAL


Francisco  S.

Francisco S. Job Checkin

Mastic sealed all boots and replaced 2


Joel S.

Joel S. Job Checkin

A low voltage wire nut was not tight enough for the common. Tightening system came on and operating properly at this time.


Joel S.

Joel S. Job Checkin

Heat performance turn up times one system. Change out filter client supplied. Inspect blower, evaporator and ductwork. Test all safety features High limits and roll outs. Best thermostat for proper operation. Tightened all wire connections. Check heat exchanger for cracks found none. No carbon monoxide a gas leak detected in home. Found two boots that need to be replaced. And the other boots need to be sealed. Leaving quote for that. System is operating at manufacturer specs at this time.


Jason D.

Jason D. Job Checkin

System was connected to a surge protector that turned unit off. Recommendation is to unplug it and plug straight into the outlet because surge protector had 3 or 4 things plugged into it in addition to the unit.


Jason D.

Jason D. Job Checkin

Walked customer thru his airflow and took Temps from all the registers. Due to ductwork layout and lack of dividers hell.have to play around with his registers to get the static pressure just right. High temp was 115 and low was 95 so he has enough heat, just needs to distribute it. Can confirm firm heat is running at this time.


Joel S.

Joel S. Job Checkin

Attempted to hook up stat for IT room with new remote sensor. The remote sensor required more wires than what was available. We will be back on Monday to do the maintenance here and I will run new wire to the it room and locate thermostat there