577 Sterling Drive
Richardson, TX 75081
972-591-0199

Local Reviews
for dallas, tx

Rated 4.9 out of 5 stars based on 175 customer reviews

Great sevice

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding service from Joel!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jeff’s review

Very professional; great identification of the problem and personal effort to show us how to resolve it

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very helpful. Took time to explain everything that was happening

Jeff is very conscientious and was apologetic when he had to leave the house without being able to fix the problem the first time. He also came out to help the wiring team when one of them didnt show up.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick response, same-day onsite service

Francisco was very helpful and worked quickly to diagnose the apparent cause of the A/C problem.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jeff the Superstar

Jeff helped me out on an emergency call on a Saturday at 9:00. Super helpful. quickly diagnosed the problem, and was very efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Another bulls-eye for this service call

Thanks, Joel .. . for being on time for identifying the problem for explaining it to me, and and fixing it quickly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dallas, tx

Jeff S.

Jeff S. Job Checkin

Completed check out, don't have properly voltage going to outside condenser, customer will call electrian.


Joel S.

Joel S. Job Checkin

Cut to buy for her to fit into return to attempt to stop the popping one unit goes off. It seems to have work


Jeff S.

Jeff S. Job Checkin

Advised customer to call a plumber to clear drain.


Francisco  S.

Francisco S. Job Checkin

Perform 1 system maintence washed codenser coil changed filter and replaced weak capacitor for turbo system cooling properly at this moment


Francisco  S.

Francisco S. Job Checkin

Perform 1 system maintence found system low on refrigerant which indicate a leak in system Joseph decided to just add refrigerant for right now I added 3 lb system cooling at this moment


Jeff S.

Jeff S. Job Checkin

Completed diagnosis, need 3/4 blower motor 115 volt, also belly band with motor universal. Jeff only and quote price.


Jeff S.

Jeff S. Job Checkin

Joel has got this service call


Jeff S.

Jeff S. Job Checkin

System was low on 410a, declined leak search. Added 4 pounds of 410a. No warranty or guarantee on refrigerant.


Francisco  S.

Francisco S. Job Checkin

Perform 1 system maintenance change filter washe condenser coil and adjusted airflow settings to 400cfm mr morales concern about system not satisfied and over working went in attic and it was 150 degrees will have Jim come out and use heat camera to find heat sources and we can be able to find solution


Joel S.

Joel S. Job Checkin

System not keeping up check charge and added 2 pounds are 22. Condenser coil needs cleaning. I advised client to do it as soon as possible. System is cooling properly at this time.


Francisco  S.

Francisco S. Job Checkin

Arrived found primary clogged restrapped with pitch, clean p trap and treated the drains water is now draining recommend customer to have a plumber re rout primary because it’s tied into master bedroom primary to avoid this isssues later on and we can re run the drain after plumber is done he will stay in contact with us about plumber rerouting primaary to a sink that way we can get this problem solve once and for all


Joel S.

Joel S. Job Checkin

AC performance tuneup times two systems. Inspect blowers, evaporators and ductwork. Verified primary drains are clear at this time. Filters are good at this time. Both systems have good temperature drop across the coil ‘s. Checked outdoor units. Test thermostats for proper operations. Refrigerant levels good on both systems. System is operating at manufacture specs at this time.


Joel S.

Joel S. Job Checkin

Mr. Pierce stated that the unit was losing temperature yesterday. Arrive today and checked the charge on the system. Charge is good. I tested capacitor ‘s. All capacitors were within specifications. Opened up side panel to condenser coil. System was clogged with dirt. This would cause the compressor to shut off temporarily and come back on once it cools down. Once I washed it compressor is quieter system is cooling properly at this time.


Joel S.

Joel S. Job Checkin

Compressor was off on a thermal limit. Call down compressor and recovered 1.5 pounds of our 410 a. System came on and I adjusted the charge to a 15° sub cool. System is 16 years old pulling 21 A and second stage.


Jeff S.

Jeff S. Job Checkin

Completed diagnostic, system was low on refrigerant Added 4 pounds of 410a. No warranty or guarantee on refrigerant. Declined replacement of system at this time.