577 Sterling Drive
Richardson, TX 75081
972-591-0199

Local Reviews
for fort worth, tx

Rated 5.0 out of 5 stars based on 3 customer reviews

Excellent service

The technician that was sent out was very thorough and precise when checking our AC and heater units. His Communication skills were very good.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service

Always the best customer service ! Great company highly recommend them

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Highly recommend! From day one great customer service and communication . Service technicians did a very thorough professional job. Helpful , kind group of professionals!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fort worth, tx

Emmanuel  L.

Emmanuel L. Job Checkin

Performed ac maintenance. Made adjustments to fan speed. Set for a 3 ton but I switched it to a 4ton. Outdoor is a single speed 4 ton from 2015. Made recommendations for drainline, negative coil and no p trap was installed. Filter will be replaced later today by the homeowner. System is cooling fine other that those issues.


Russ T.

Russ T. Job Checkin

Completed with water leak on 2023 trane upflow in closet 2.5 ton our install under pnl. Found evaporator coil froze up with ice. Turned heat on to melt ice and find out issue. Refrigerant levels were good. Most likely was a very dirty filter. Customer did mention filter was dirty. Unit running and not leaking at this time.


Emmanuel  L.

Emmanuel L. Job Checkin

Both systems are day to day at this point. Would not expect either one to cool well in present state. Leaving options for replacement of both upstairs and downstairs systems. $3k off each system if we replace both.


Emmanuel  L.

Emmanuel L. Job Checkin

Checked system, came across blower wheel broken in housing. Motor has also failed with its loose bearings and lubricant leakage. Ordered the OEM parts from carrier. They will be shipping those over and that gentleman on the phone said 5 days lead time. Will check back on next Tuesday. Mr. Schaffer was not interested in replacing furnace or system as it’s a little out of the budget.


Jay J.

Jay J. Job Checkin

One system cooling tune up. Inspected indoor coil and blower motor. Tested system pressure and subcooling. Inspected fan motor, capacitor, and contactor. Recommended installing new disconnect for condenser Recommended blower wheel pull and clean or replace blower wheel Recommended new fan motor for condenser Recommended charging system with 410A to the proper subcooling of 13 See estimate


Emmanuel  L.

Emmanuel L. Job Checkin

Returned to install evap motor, belly band, turbomini capacitor and blower wheel. System heating properly.


Collin F.

Collin F. Job Checkin

complete


Collin F.

Collin F. Job Checkin

completed install form


Collin F.

Collin F. Job Checkin

Found the control board to be bad. Customer will replace it himself. Due to the style of system the unit should all be replaced at one time to avoid further issues. Left pricing for new units customer will return a call back if they want to move forward.


Joel S.

Joel S. Job Checkin

Heat performance tuneup times one system. Found no issues with heat pump at this time.


Ray L.

Ray L. Job Checkin

2 1/2 ton Trane Full Gas system


zwschmitt@gmail.com

zwschmitt@gmail.com Job Checkin

Zac Preformed inspection of building 18 units. was not told which unit but just building 17. I assumed that it was the heavily damaged unit. it is running but does look a bit low on refrigerant. there is no electrical cabinet door the motor is leaking oil. wires are too small for unit size. only option with us is to replace the outdoor units as there are numerous code violations for every system. the only storm damage looks to be that one unit.


Joel S.

Joel S. Job Checkin

AC performance tuneup times one system. Client changes his own filter. Inspect blower, evaporator and ductwork. Primary drain is clear and flowing at this time. Check thermostat for proper operations. Check outdoor unit. Refrigerant level is perfect at this time. Checked passer in contactor. System is cooling properly at this time.


Justin S.

Justin S. Job Checkin

Customer currently has a 2 zone system (tstat upstairs and one Downstairs ) it's a 5 ton upflow heatpump with a closet door opening of 30" . The current honeywell zone board is working fine and can be kept . Also the 46x32 slab is in good condition . Condenser is on right side of house with no gate or fence (easy access) air handler is up the stairs in first door. I also filled at a pre I stall form


Joel S.

Joel S. Job Checkin

Heat performance tuneup times one system. Filter was good. Inspect blower, evaporator and ductwork. Test amp draw on 10 KW heat strips. Check outdoor unit. Refrigerant level good at this time. Test capacitor and check contactor. Test defrost cycle. System is heating properly at this time.