Performed air conditioning maintenance , one Lennox straight electric system from 1990s. Heat strips are not on while cooling. Coil has seen better days. System is still cooling but homeowner should plan for failure of this system. Electing to keep everything as is today.
Performed heating maintenance on Lennox air handler Upflow in closet. Straight electric one circuit hooked up to two breakers in furnace. 15kw. 5 mfd run capacitor was reading 1.3mfd. Replaced with new turbo mini. Talked to homeowner about possibly getting estimates for system replacement due to age, coil leaking slowly but at this time he is not interested about making that investment. System heating and cooling at todays visit.
Completed heat tune up and sent to customer. , found several issues that I presented to customer . Replacement contactor is all he wanted to fix today.