Very professional on arrival. Clear explanation of issues & problem solving.

No major complaints. A closer arrival time would’ve been a bonus for me “technician is on his way at 8:06, I was not expecting an hour and 15 min wait, just needed that little info to plan the day. He finished rather quickly & didn’t mind explaining things twice as my husband came in just after he had told me everything.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lavon, tx

Joel S.

Joel S. Job Checkin

AC performance tuneup times one system. Found no issues with four year-old system at this time. Filter is an AprilAire 2300. Drains are flowing at this time. Attic is foam insulation on the rafters. Washed condenser coil and checked all electrical on outdoor unit. System is operating at manufacturer specs at this time. I am recommending surge protection for indoor and outdoor. Estimate will be sent via email.


Joel S.

Joel S. Job Checkin

Yearly check up times one system. Inspect blower, evaporator and ductwork. Verified primary drain is clear at this time. Refrigerant level is at manufacturer specifications. System is cooling properly at this time.


zwschmitt@gmail.com

zwschmitt@gmail.com Job Checkin

Zac house is vacant and was instructed to enter by phone. upon arrival found air handler sealed and a screw in the door so I was unable to fully open it to inspect system. return duct is too small and restricts system. supply plenum is also way off in size. filter is dirty but ceiling is 12+ feet so I was unable to pull it out. both of these affect refrigerant pressure I also could not inspect coil for impaction due to strap and sealing. found middle of condenser pad washed out and tipping over which will cause issues. pad is also falling apart. all electricals outside are in range but there are burn marks on defrost board which are showing a future failure. resting freon pressure looks okay but the real test while it's running is off. it is showing symptoms of what I mentioned above and it could be low but without being able to access coil and filter, and proper ductwork I cannot be certain. and due to no coil access a leak search cannot be Preformed. system is cooling at 24 degrees w


Joel S.

Joel S. Job Checkin

Home inspection


Nicholas S.

Nicholas S. Job Checkin

Acquired email and rough measurements for estimate. If the estimate is accepted we will need to run heat load calculations and plan the duct runs. See pictures, we will get back to them with pricing.


Samuel H.

Samuel H. Job Checkin

Apon arrival checked in with customer the following are my findings Found the Drains clogged and the ducks unsealed remediated both system is now working better informed the customer if drain problems keep on persisting we're going to have to separate the drain lines they understand please see pictures attached