577 Sterling Drive
Richardson, TX 75081
972-591-0199

Local Reviews
for richardson, tx

Rated 4.9 out of 5 stars based on 105 customer reviews

Thorough and Efficient

Francisco was polite, efficient, thorough and problem solving.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super fast and great customer service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional service

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Problem Solved

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, awesome price!

The technician was knowledgeable, respectful and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very satisfactory

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Working with AC Pros has been awesome, everybody is helpful and nice.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Francisco is the man!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Jeff is awesome!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and knowledgeable

Joel is great and very responsive

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for richardson, tx

Joel S.

Joel S. Job Checkin

Set zone dampers where each zone will open and shut accordingly. System is operating properly at this time. # no


Joel S.

Joel S. Job Checkin

System not keeping up. Check charge and found system to be at least 2 pounds low on our 22. Gloria stated she would like to see what her home warranty will pay for.


Francisco  S.

Francisco S. Job Checkin

Arrived to t stat off found wire loosed tighten connection system cooling properly


Francisco  S.

Francisco S. Job Checkin

No duct fans in attic will consult Russ on what needs to be done and contact nikki on price qoute


Joel S.

Joel S. Job Checkin

John and I walked around to see which vents were blowing and which were not blowing. Three vans downstairs never blow. System is keeping 72° inside the home downstairs. 75 upstairs.


Francisco  S.

Francisco S. Job Checkin

Perform 2 system maintence checked pressure and split upstairs system was low on refrigerant indicating a leak sandy wanted to bandaid so I added 2 lb system both systems cooling at this moment


Joel S.

Joel S. Job Checkin

Lisa stated that the upstairs unit was malfunctioning. Check the filter and it was OK needs to be changed though check thermostat. Put system into second stage and check charge. Refrigerant level is good at this time. Found condenser coil completely clogged with Cottonwood. Cleaned off coil and unit next to it. System is cooling properly at this time.


Jeff S.

Jeff S. Job Checkin

Connected and secured primary drain line on inside and outside of house, For upstairs.


Francisco  S.

Francisco S. Job Checkin

Perform 1 system maintenance change filter customer supplied washed condenser coil checked split and pressures drains are not sloping correctly and need to be reran they run over 50ft and advised Mary to have a plumber and reran drains from bathroom sink up to the attic and have us come out and tied into condensating line that way she don’t have problems in the future can confirm system is cooling at this moment


Joel S.

Joel S. Job Checkin

No cool single system. Client stated that it didn’t seem like it was keeping up. Went to outdoor unit and found common wire burnt on the run capacitor. 55+5 run capacitor was basically dead. Removed and replace with turbo. Part comes with five year warranty. Check charge and refrigerant level is good at this time. System cooling properly at this time.


Francisco  S.

Francisco S. Job Checkin

Arrived to no cool dignosed compressor not running installed turbo condenser is from 1994 showing signs of age and compressor amping high customer wants a qoute on replacing condenser will have Comfort consultant come out and give him options tomorrow can confirm system is cooling


Francisco  S.

Francisco S. Job Checkin

Arrived to compressor not coming on dignosed a bad capacitor replaced with turbo system cooling properly now customer had senior citizen/military 10% off coupon


Francisco  S.

Francisco S. Job Checkin

Arrived to clogged lines cleared installed quick last and blew with nitrogen advised Adam to get a plumber to go under house to rehang the drains from the outside it looks like drains backpitching he said he would do it himself drains clear at this moment


Jeff S.

Jeff S. Job Checkin

Replaced condenser fan motor for #1 system, 22volt 825 rpm. Checked charge everything is working fine.


Jeff S.

Jeff S. Job Checkin

Downstairs system was on R22, charged with 5 pounds. No warranty or guarantee on refrigerant.