- Upon arrival knocked on door and David Farrington/homeowner answered. - Verified information provided to technician over phone. - Started diagnostics on outdoor condenser due to facts presented by homeowner. - Upon walking up to condenser …technician could hear contactor engaged and compressor failing to start. - Found failed/compromised 45/5 dual run capacitor. - Verified valid/current 5 year standard parts warranty through Lennox - Homeowner authorized replacement of capacitor and purchased replacement 20x25x1 filter. - After installation of replacement capacitor and filter……ran minor AC/cooling diagnostics. - Checked electrical components on condenser. - Compressor and condenser fan motor amp draw within manufacturer operating specifications. - Refrigerant charge is within manufacturer operating specifications. - no water retaining - 18°F temperature drop across the coil after repairs made. - System currently cooling, draining, functioning properly again at this time. - Recomm