9006 Westfield Dr
Rowlett, TX 75088
(469) 476-4846

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 537 customer reviews

Disappointed

Jacob is on training and he dose not have the total experience. He flushed clean the hvac drain and he didn’t know that he needed to cover the bathroom sink, the whole thing exploded messing up the whole bathroom. They sent other tech to clean up Jacob’s mess. Whatever Jacob did ended up clogging the 2 bathroom sinks. Cost me $350 to fix Jacoba mistake. I am very unhappy with the technician, don’t ever have Jacob as your Techician!!!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jacob is an awesome young man!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Superb Service

Air Force One Plumbing, Heating and Air Conditioning was terrific. They were professional, timely, and accomplished the task at hand. We highly recommend them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Problem solved.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Review

Again brought wrong air filter

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great folks!!

Honest, fast service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough, Great service !

Jacob arrived on time and was very thorough with his inspection of our A/C unit. He explained everything about what he did and found.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super workmanship

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Tara R.

Tara R. Job Checkin

Seasonal maintenance


Tara R.

Tara R. Job Checkin


Tara R.

Tara R. Job Checkin


Tara R.

Tara R. Job Checkin

Leak was found inside the evaporator coil via the uv dye.


Tara R.

Tara R. Job Checkin

45 7.5 run capacitor was replaced as well as the jumper between contactor and capacitor


Tara R.

Tara R. Job Checkin

Inspected inside unit aprilaire filter. Blew out condensate drain. Checked refrigerant levels found the levels slightly low.


Javier  L.

Javier L. Job Checkin

2 customer supplied toilets, 10 angle stops and 2 supply lines installed


Tara R.

Tara R. Job Checkin

Cst mentioned slight gas smell by back door the other night but nothing found during maintenence inspection. All electrical and mechanical readings to standard. Outside unit found to be lightlyclogged with debris. After rinsing no other faults were found. Air filter replaced 20x25x4


Tara R.

Tara R. Job Checkin

Replace drain line and float switch


Tara R.

Tara R. Job Checkin

Condensate line clogged at float switch must replace line from unit to floor.


Tara R.

Tara R. Job Checkin

Air filter clogged and replaced with customer supplied filter. Recommended regularly changing. 55+5 dual run capacitor almost completely dead and found to be the cause of no cooling.


Tara R.

Tara R. Job Checkin

Replaced armaflex on outer refrigerant lines, covered first 12' of condensate line, sealed mentioned duct insulation, removed insulation from register.


Tara R.

Tara R. Job Checkin

Inspected inside units found one had tripped its breaker no cause found upon restart. Outside units all operating normally. Air filters cleaned and replaced. Quote given to come back out and install arma flex on the 24th 8-10am.


Tara R.

Tara R. Job Checkin

Inspected indoor unit cleaned air filters. Everything found to be running as intended. Outside unit does not have disconnect must address this issue. All available electrical tested and operating to standard. Inspected air purifier found that timer needed to be reset.


Tara R.

Tara R. Job Checkin

Inspected indoor unit found it to be operating within standard. Air filter needs replaced for future reference it is 20x25x4. Outside unit also inspected and found to also be operating to standard.