2331 Whitfield Industrial Way
Sarasota, FL 34243
941-739-1511

Job Locations
for north port, fl


Map of North Port FL
Brandon P.

Brandon P.


Job Checkin

AH Cleaned and treated drain line Looked over low and high volt components Got temp split and static pressure readings Checked heat Added lg pan treatment Checked Uv good till next visit Checked filter needs replaced CONDENSER Checked pressure Looked over low and high volt components Rinsed coil RECOMMENDATIONS UV replacement bulb Start assembly RUN CAP, CONTACTOR parts and labor warranty $99 deductible SURGE PROTECTORS PROTECT SYSTEMS FROM SIGNIFICANT POWER FLUCTUATIONS The freeze Protection Lockout Switch, MODEL CPLS, is a temperature sensing control, used to act as a safety against Evaporator Coil freeze up. It is designed to mount on the surface of a 3/4" or 7/8” suction line. Electrically, it is wired in series with the "Y" lead from the thermostat or zone control panel, to the compressor contactor coil or relay. The switch breaks (opens) shutting off the compressor when the temperature of the pipe drops below 37 F. The switch will reset (close), restarting the comp