3270 Kino Ave
Kingman, AZ 86409
888-221-4702

Local Reviews
for bullhead city, az

Rated 4.8 out of 5 stars based on 987 customer reviews

Great communication form start to finish!

Great communication! Will be our go to for the future!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service.

All was great, except when they finished and left they forgot to turn back on the electrical breaker for the water heater.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing Service!!

Brandon was personable, professional, and just a super nice guy!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Above and beyond professionalism!

Best service from any local business ever!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Yes I had your tech Mike great guy very knowledgeable and diagnosed the problem quickly and fixed it very happy with your service thank you so much

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Christian from Ambient Edge showed up when he said he would and gave us all the information we needed to make a decision on our water heater.

  • Overall Experience
  • Quality
  • Price
  • Convenience

There is excellent service and this wasn’t it

The service was FAR beyond excellent (you thought this was a bad review). The young man was professional, polite, knowledgeable and quick. My dog took to him right off and he is a hell of a judge of character!! The landlord paid so I can’t comment on the price. Everything else is great. I’d love to work out something for my podcast to get the word out about y’all . If that interests you call me : Mike 928-605-5081 or HeathenCowboy74@Gmail.com

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service

Quick & Great service technician very informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

work review

very professional very knowledgeable very courteous took a while but got the job done great job Nick

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job well done

Best job ever

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good

  • Overall Experience
  • Quality
  • Price
  • Convenience

What the right thermostat for two-stage air conditioner

I had the wrong thermostat for a two-stage air conditioner, fixed it. Excellent service thank you guys.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!!

Nick and his co worker were polite friendly increbibly knowledgeable and very awesome!!! Thank you so much for employing them!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bullhead city, az

Larry G.

Larry G. Job Checkin

On arrival found unit with ice over indoor coil De ice with heat pump function Restart unit and check pressure amps on fan motor Found unit to be set at 70 with customer unknowing how much cooling this unit can handle Unit running proporly at this time inncooling at 76 Reviewed operation with customer


Larry G.

Larry G. Job Checkin

Installation of 15.2 SEER 2 package system on roof. Remove and dispose of existing equipment. Transition to existing ductwork. Replace and enlarge current return duct and filter rack. Replace Supply duct from uni. Includes new equipment stand. Includes new Wi-Fi Thermostat. Includes County Required Permit. 10 year parts warranty. 10 year compressor warranty. 2 year labor warranty. VIP plan discount applied. VIP plan added.


Nicholas S.

Nicholas S. Job Checkin

No cool. Brand new 4 ton Goodman coil and condenser we installed 7/31/23. Customer was complaining of low air flow since installation and unit would not get below 80°. Upon arrival I found the compressor and the Evap coil partially frozen. Checked refrigerant pressures, amp draws, blower speed, and blower cap. Determined there is an airflow issue with the system but unable to determine where the cause is. Will submit install issue form to have install come out and inspect duct connection as well as the underside of the coil to make sure there is no blockage.


Nicholas S.

Nicholas S. Job Checkin

No cool. 2017 nordyne package heat pump for mobile home. Upon arrival I found the thermostat with a locked out screen. Removed from wall, removed batteries and reinserted them, and reset the thermostat and unit fired right up with no issues. Let system run while checking unit and it brought the house down from 105° to 96° before leaving. Advised customer that I did write up and estimate to replace the thermostat if issue happens again, but unit is running and cooling as designed at this time.


Trevor H.

Trevor H. Job Checkin

Technician found reach in cooler used at serving window has bad CFM that is squealing. Will need to install new CFM and test operations. Arrived n site with new motor. Started pulling old motor out once tech was able to disconnect the wiring he found the the old motor had a 3 pin wiring harness and the new motor only had two. Old motor only used two of the pins the the new one would not match up properly. Tech will let kandyce know and have correct motor ordered. Will also let office know and pause job. Arrived on site with correct motor start trying to remove the motor and found all the hardware o be in metric. Ran to store and grabbed metric ratchet set. Came back and removed motor installed new one and wired it to old plug. Turned unit on. After anti short delay everything came on and started cooling properly. Collected payment and signatures. All work is complete.


Nicholas S.

Nicholas S. Job Checkin

No cool. 2005 Amana split gas for mobile home. Found condenser fan motor out on thermal overload. Cooled motor off and started motor again. Checked amps, motor was pulling 2.2 amps rated for 1.8. Recommened to customer to replace motor but also discussed replacement options due to age of equipment and r22 phase out. Customer just wanted motor repalced today. Replaced motor and tested operation. No other issues found at this time. Refrigerant pressures seemed off, but that is due to high heat load in the house.


Nicholas S.

Nicholas S. Job Checkin

No cool. 1982 carrier gas pack 5 ton rtu. Upon arrival I found the batteries dead in the thermostat and replaced them with customer supplied batteries. Went on rooftop and unit was now running. Checked r22 refrigerant pressures, amp draws, capacitors and delta t. When pulling disconnect the pull handle broke off in my hand, unable to disconnect power to unit at disconnect. Could smell burning and the handle had obvious melting spots in it. Found unit low on r22 refrigerant, compressor pulling high amps, compressor capacitor reading 0 out of 65, hard start capacitor reading below specs, and blower capacitor reading 1 out of 10. Went over options with customer and he is interested in replacing the system, but has a home warranty and would like to see if the can help offset the cost. Advised customer for safety reasons with that disconnect, I left the breaker off to the system so it was not getting power. Unit is not running at this time.


Brandon H.

Brandon H. Job Checkin

Technician found mechanical temp controls not accurate. Will need to install new temp control and test operation. Arrived on site to find freezer at 25 degrees F. Recently worked on unit not running. Checked unit and had proper voltage to condenser. Found HPS not sending voltage through. Attempted to reset HPS manual reset. HOS would not reset. Hooked up gauges and bypassed HPS. Powered unit on and it ran. Unit was not hitting 410 PSI at which safety would open. Bad HPS. Went to supply house and picked up mechanical HPS and installed it under warranty. Replaced unit temp control panel n freezer at evaporator. Powered unit on and verified operations.


Nicholas S.

Nicholas S. Job Checkin

No cool. 2021 American standard 3.5 ton condenser with a 2002 Trane 3 ton Evap coil and furnace. Upon inspection I found the unit completely frozen up. After thawing unit I found that there is a non oem txv installed on the Evap coil and that r410a refrigerant pressures appear to be very low which caused the unit to freeze up. After discussing with the customer I found that another company had come out and replaced just the condenser in 2021. Explained to the customer that with the age and stat of the equipment the least that needs to be done would be to replace the Evap coil and furnace with an ahri match to the outdoor equipment, and if that is unable to be done due to the new efficiency requirements to replace the entire system. Customer has homeowners insurance through farm bureau and they are hoping that they will take care of everything after the customer pays the deductible. Filled out paperwork as best as we could and explained to customer that we would need confirmation of pay


Larry G.

Larry G. Job Checkin

Put tape and dope on leaking threads on RO tank. Resolved


Larry G.

Larry G. Job Checkin

Technician found system low on refrigerant. Will need to recover existing refrigerant. Perform a nitrogen leak search. Attempt to repair leak if found. Install new filter drier. Pull vacuum. Convert to R427a refrigerant to include ac renew. More quotes may follow. Ambient Edge recommends system replacement over repairs due to age and condition. Returned to site. Checked in with management. RTU #3: Performed leak search with electronic leak detector. Inspected evap and condenser coils for any leaks. No leaks detected in coils. Found leak to be at the discharge king valve. Attached a T-fitting connector to the king valve to stop leak. Found secondary drain pan with lots of condensate water in it, indicating a drain problem in the primary drain line. Cut the primary drain line to blast nitrogen pressure through the line to clear it of any debris. Reconnected primary drain line with a pvc coupling. RTU#3 air handler: Found secondary drain pan with a drain line that is sloped upwards,


Brian A.

Brian A. Job Checkin

Pick up temp ac 7nit


Larry G.

Larry G. Job Checkin

Repipe in 3/4 and 1/2 inch pex, angle stops, supply lines, expansion garbage disposal, RO, and hydro edge all installed. No leaks resolved


Nicholas S.

Nicholas S. Job Checkin

Came out and reset everything on the system and got unit running until new parts come in. Ordered new control boards for air handler as well as new media thermostat that is under warranty.


Nicholas S.

Nicholas S. Job Checkin

Warranty call back. We just replaced capacitors and contactor and found loose wire connection for common wire coming off of conatctor to capacitor that caused the wire to burn up and melt. Replaced wire and tested unit. Found no other issues. Unit is running and cooling as designed at this time.