3270 Kino Ave
Kingman, AZ 86409
888-221-4702

Local Reviews
for fort mohave, az

Rated 4.9 out of 5 stars based on 235 customer reviews

Quick and Effective Service

He was quick and thorough in fixing the problem. However his ladder damaged my door in my laundry room.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best yet!! Great experience.

Jonathan is professional in every way. Knowledgeable, efficient, experienced, friendly and polite. An excellent representative of Ambient Edge.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

He was kind and helpful. Also fast.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Love this company!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Kind and honest

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Customer Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Kind and Knowledgeable

Nick and Aaron were very kind and knowledgeable!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank you for the GREAT Service!!!

Nick was professional and knowledgeable. Thank you for being prompt and taking care of us.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

My appointment for my yearly summer service was performed by Nicholas. He did an excellent job plus he discovered I had a water leak and my carpet by the patio door was soaked. Nicholas used my carpet shampooer to get up all the water from the carpet and helped me get a plumber. He is an excellent representative for Ambient. He is courteous and very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic!

Awesome service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

OUTSTANDING SERVICE

Louie Navarrete was our plumber that installed our Water Heater. He was friendly and a pleasure to deal with. He showed up as scheduled, greeted us, inquired as to what we needed and quickly and efficiently went to work on installing the Water Heater and Pressure expansion tank. He double checked his work to insure the proper installation. He was knowledgeable and instructed us as to the proper care of the Water Header and Expansion Tank. He represents the company in an outstanding manner and I would recommend him to anyone. Thank You Louie for a Great Job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fort mohave, az

Devon R.

Devon R. Job Checkin

Arrived on site. Gave the customer an estimate to replace the cartridge for the single handle shower valve. Also recommend installing a softener system. Customer accepted the estimate for the shower cartridge. Customer stated they will request an estimate for a softener install at a later time. Replaced cartridge and tested for functionality. Spout now open and closes normally. Customer happy.


Christopher W.

Christopher W. Job Checkin

Replace ac furnace and coil attic access in bathroom reconnect to existing ductwork and electrical


Larry G.

Larry G. Job Checkin

On arrival system is running but intermittently shuts down even though thermostat is calling. Fault code L0, problem in control board. Outdoor temp was 120 and according to display, control board temp was 147. System may be shutting down to protect control board but need to talk to tech support. Arrived too late to call techs support, they are east coast and close by 3pm. Need to reschedule for 12-1 another day Spoke with Bosch tech support and we diagnosed the system with a bad inverter board as well as bad compressor. Submitted parts order sheet and will be waiting on parts to arrive. Replaced compressor and inverter board. Tested system operations and everything is working well at this time. Advised home owner to run system as he normally would and monitor if temperature is being satisfied.


Brian A.

Brian A. Job Checkin

Found outdoor fan motor running very slow and very high amps. System shutting off on high pressure safety. Run capacitor for fan internally shorted, needs new capacitor under parts warranty Returned with new capacitor. Installed part and tested system operation. Everything working normally at this time.


Larry G.

Larry G. Job Checkin

Install parts per workorder 1/ single pole contactor due to pitting at main power terminal Recheck unit on replacment of part PRESSURE AMP and RUN CAP on Compressor Fan motor Data log infor in control panel Test unit in cool At Tstat uit running propoly at this time of services


Brian A.

Brian A. Job Checkin

Found both ac units not cooling. Determined that capacitors are burnt out. Called owner to approve repairs. Recommended seasonal preventative maintenance. Replaced capacitors and tested operation, compressors and fan motors workin* ok, refrigerant ok. Declined maintenance agreement Customer authorized charging cc on file


Larry G.

Larry G. Job Checkin

Found Tstat to be incorrect model Recoomend S30 not and S40 Unit will not communicate propoly with out rewire and customer would like to have large screen


Travis M.

Travis M. Job Checkin

Arrived on site customer saying no water to refrigerator, no water at refrigerators angle stop. Previous work didn’t include water to fridge. Need to charge for more time to find out why there’s no water to the angle stop. Customer wants to wait to see if the problem can get fix before signing up for vip. Customer spent 1500 with us and wants a discount. Also fixed 2 leaks on reverse osmosis under kitchen sink. Done for now


Larry G.

Larry G. Job Checkin

On arrival found unit with return duct sucked into return due to broken flex Remove / cut ductwork Reconnect ductwork to unit with duct straps and duct tape Check airflow to be correct Summer maint VIP sign up Check pressure Amps on fan motor blower and compressor Check run cap and relay Inspect indooe outdoor coil to be clean Filter just replaced Data log unit inside control panel and ST Test unit in cool at Tstat unit running proporly at this time of repaire and VIP summer maint Please review recommendation


Larry G.

Larry G. Job Checkin

Capacitor was reading less than half of manufacturer specifications recommend replacement/ replaced capacitor checked rechecked amp draws and delta T everything looks good and is working as intended at this time


Larry G.

Larry G. Job Checkin

Check 1 unit Ac Check pressure amps on fan and compressor .blower motor Check relay contactor and run cap Found unit to have bad run cap and contactor Removed and replace 55mfd and 2 pole contactor Filter clean Clean indoor and out door coil Data log info inside control panel and ST Test unit in cool at Tstat unit running proporly at this time of service in cool First Service completed today for VIP No recommendation at thia time


Larry G.

Larry G. Job Checkin

Cooling maintenance on a r-22 Goodman unit checked capacitors amp draws and pressures everything looks good and is working as intended at this time.


Larry G.

Larry G. Job Checkin

Arrived on site and inspected under sink. 2 valves with corrosion. Garbage disposal mount was not tight causing it to leak. Garbage disposal is fine and functioning properly. Customer also requested quote for install on RO system. Inspected area for softener install. Loop already in place. Gave customer estimate for installs. Customer accepted estimate. Installed customer supplied softener system. Tested all connections. No leaks. Programmed softener and added 4 bags customer provided salt. Installed 2 new dual angle stops. Tested. No leaks. Installed customer provided RO system and removed air gap for faucet install. Tested system. No issues or leaks. Informed the customer about purging procedure. Left dishwasher connections unhooked as dishwasher will be installed today or tomorrow by appliance company. All connections good. No issue. Collected payment. Customer satisfied with todays service.


Larry G.

Larry G. Job Checkin

On arrival found unit with oil stain st compressor suction line at compressor Found unit with no REFRIGRANT Charge unit with nitrogen and found leak at Compressor suction line cracked at compresssor. Housing No fixing unit at this time unit would need a new compressor and is not adviced at this time Unit is off at this time


Larry G.

Larry G. Job Checkin

Found unit icing at arrival Inspect unit pressure to find restriction at filter drier and piston Inspect unit to have had leak seal and ac renew added to it Check amps on compressor and fan motor check blower motor Filter clean Unit running at this time of service with reatriction and leak at service cores Please review estimate for repaire Or please call you schedule CSR for new unit