8021 W. Gulf to Lake Hwy
Crystal River , FL 34429
352 795 2665

Local Reviews
for homosassa, fl

Rated 5.0 out of 5 stars based on 1078 customer reviews

Fantastic job!

He was quick and got the heat on very quickly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

GOOD SERVICE NICE GUY THANK YOU

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast professional service

Tech did a great job, Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Great orice

Guys were great explained everything great job runs great.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Job!

Matthew was quick and efficient. He came out first thing in the morning. Repair was quick. He seemed very knowledgeable about his profession. Thank you for fixing our AC Matthew!

  • Overall Experience
  • Quality
  • Price
  • Convenience

One time, Neat and well done

I've dealt with your company for years and your service today was excellent as always

  • Overall Experience
  • Quality
  • Price
  • Convenience

On the money for service and caring.

Responded immediately to our call Saturday morning and was there by ! and completed shortly after.

  • Overall Experience
  • Quality
  • Price
  • Convenience

BEST SERVICE

  • Overall Experience
  • Quality
  • Price
  • Convenience

AWESOME

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for homosassa, fl

Darin G.

Darin G. Job Checkin

Call customer back to schedule cleaning. Nothing wrong with system other company fix system.


Darin G.

Darin G. Job Checkin

Explained defrost cycle. System operating normal.


Don K.

Don K. Job Checkin

Reset breaker system running normally at this time instruct customer customer wants to wait until New Year to purchase system he will call us when he is ready


Matthew J.

Matthew J. Job Checkin

Customer called due to heat not operating correctly found system with defective thermostat replaced warranty thermostat checked operations in heating all ok. System operating correctly at this time.


Darin G.

Darin G. Job Checkin

Reset breaker in od disconnect check amp draws to be normal and connection to be tight.


Matthew J.

Matthew J. Job Checkin

Custer had no heat unit is a straight cool thermostat set for heat pump. Set thermostat for straight cool heat operating correctly at this time.


Don K.

Don K. Job Checkin

Checked overheat found trip breaker reset breaker tested good instruct customer only has a 5kw heater in it.


Darin G.

Darin G. Job Checkin

wires going to heat strip were melted. Cleaned wires and secured correctly. Heating at 41 amps. Bill customer


Matthew J.

Matthew J. Job Checkin

Contract tune up complete cleaned both indoor and outdoor coils checked system operations in heating and cooling all ok. Cleared drain flushed with dawn and water verified system draining on its own added condensate tablets to drain pan. System operating and draining correctly at this time.


Robert H.

Robert H. Job Checkin

FOUND UNIT LOW ON REFRIGERANT AND BAD RUN CAPACITOR. GOT UNIT RUNNING. CUSTOMER BOUGHT NEW EQUIPMENT. TOOK DEPOSIT OF $500 OF REPLACEMENT. BALANCE WILL BE DUE IF INSTALL CANCELED.


Darin G.

Darin G. Job Checkin

completed maintenance


Robert H.

Robert H. Job Checkin

FOUND UNIT COMPLETELY OUT OF REFRIGERANT. STATIC CHARGE WITH NITROGEN. FOUND LEAK AT SUCTION LINE WHERE ROOFING NAIL PENETRATED COPPER LINE. REPAIRED LEAK . VACCUMED TO 410 MICRONS. RECHARGED WITH NEW R410. UNIT IS COOLING NORMALLY AT THIS TIME.


Darin G.

Darin G. Job Checkin

Replaced run capacitor.


Robert H.

Robert H. Job Checkin

Found indoor blower run capacitor blown. Replaced with new 10 microfarad run capacitor. System is cooling normally at this time


Dale F.

Dale F. Job Checkin

Air-conditioning and heat strips on at the same time, found that the thermostat wire has been chewed up by some kind of animal, bare wires touching, disconnected the white wire so at this time only the AC will run, there is a possibility that has the wire deteriorates the AC could run and never shut off if that were to happen turn off the breaker to the machine, Will need a new thermostat wire customer has a home warranty service that is going to come out and repair it, Thank You