Matt  C.

Matt C. Job Checkin

Found the humidity settings turned off. Adjusted the settings to allow dehumification. Corrected the humidity reading by 8 % and tested the cooling and dehumification.


Matt  C.

Matt C. Job Checkin

Found that the air handler breaker was tripped. Checked all the connections and ensured they were secure. The heating element is pulling 41.7 amps. The customer told me before they replaced the breaker they had to push on the breaker to get it to connect to the electrical panel. The panel itself could be damaged at this point causing the breaker to over heat and turn off.


Matt  C.

Matt C. Job Checkin

Completed the maintenance inspection.


Matt  C.

Matt C. Job Checkin

Repaired the refrigerant leak, pressure tested with Nitrogen, pulled a vacuum down to 450 microns and adjusted the Subcooling to 10 degrees. Two year labor warranty on today's refrigerant repair.


Matt  C.

Matt C. Job Checkin

Installed the infinity controller and rewired the system. Programmed the thermostat and explained how to operate the stat. Also noticed a small leak at the air handler. We will be returning to repair that issue at another date.


Matt  C.

Matt C. Job Checkin

Found a blown fuse due to a low voltage short at the condenser. Repaired the wire and replaced the fuse. The system is up and heating.


Carolyn R.

Carolyn R. Job Checkin

Found drain plugged between condensate pump and primary. Cleaned drain and pan. Cleaned pump and treated all


Carolyn R.

Carolyn R. Job Checkin

Tune up on system ran on heat 66° outside. Found no issues Mail copy for invoice address 3612 37th st. Extension beaver falls p.a 15010


Carolyn R.

Carolyn R. Job Checkin

Completed the maintenance inspection.


Cliff P.

Cliff P. Job Checkin

10 year parts and 1 year labor warranty


Cliff P.

Cliff P. Job Checkin

Checked over the system. The unit is working as designed. Recommend having a maintenance inspection to look further into the system.


Cliff P.

Cliff P. Job Checkin

Service call completed, upon arrival found system not operating due unit was out of refrigerant, gas up system and traced with a leak detector, found leak in the evaporator coil, advised client systems conditions and provided with options and recommendation , system down and out at this moment


Cliff P.

Cliff P. Job Checkin

Completed the maintenance inspection.


Cliff P.

Cliff P. Job Checkin

Cut duct work back for roofers around at 945 for got to arrive.


Cliff P.

Cliff P. Job Checkin

On arrival found the thermostat set for 78 degrees with a 52 percect humidity. The temperature inside was 76 degrees with a 80 percent humidity reading. The humidity reading was 20 percent off. Adjusted the humidity by ten percent and wasn't able to go more than 10 percent. Recommend replacing the thermostat.