8021 W. Gulf to Lake Hwy
Crystal River , FL 34429
352 795 2665

Local Reviews
for safety harbor, fl

Rated 5.0 out of 5 stars based on 4 customer reviews

Awesome experience and very fair prices

The whole process with Bay Area Air Conditioning was a pleasure. Very straight, open and fair price quoting from their sales person Jim Horton; and awesome team of technicians led by Mark who were very knowledgeable and did a perfect install. I highly recommend Bay Area air conditioning.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceeded our expectations.

We called for service and was thrilled to learn that they would be able to send a technician out the same day. The technician arrived earlier than expected and notified us when he was on his way. He was so professional, incredibly knowledgeable and nice and was able to resolve our issue promptly. We can’t express what a great experience it was to work with Bay Area Heating and Air and feel they are a service you can truly trust!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Your company employees show up on time, they are well mannered and trustworthy as well. They are quick and to the point and I don't feel any distrust in what they tell me is wrong. They always fix it and they never overcharge. I am so happy we found your company. We will never call another company to work on our air conditioners. Thank you for being an excellent company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

There is a reason I have used Bay Area A/C for over 25 years. They have always been consistent, professional, punctual and reliable. I would highly recommend them (angry have) to friends & family.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for safety harbor, fl

Cliff P.

Cliff P. Job Checkin

Replaced 5 kw heat package with broken terminal block. Restarted and tested cooling.


Cliff P.

Cliff P. Job Checkin

Replaced 5 kw heat package with broken terminal block. Restarted and tested cooling.


Marc M.

Marc M. Job Checkin

Need to return with correct heater sticker and unit 1 and 2 labels for inside and out


Jeff M.

Jeff M. Job Checkin

Upon arrival the humidity was higher than set point for cool. The overcool function was disabled but fan would kick on to dehumidify but no compresser so fan only blowing wascausing humidity to rise. I explained to homeowner that system will cool 2 degrees below set point. I all went to condenser and the unit was very loud and vibrating. The blade looked as if it was out of balance. I ordered new blade and motor in case motor is damaged as well.


Cliff P.

Cliff P. Job Checkin

16 SEER 10 YEAR PARTS AND 1 YEAR LABOR


Cliff P.

Cliff P. Job Checkin

16 SEER 10 YEAR PARTS AND 1 YEAR LABOR


Cliff P.

Cliff P. Job Checkin

Found the system a little low on r22. Adjusted the superheated from 31 to 14degrees. 64 degrees coming from the supply vent. Vacuumed the drain system. No charge. Customer is having a new system installed on 9/30/2020


Cliff P.

Cliff P. Job Checkin

Found the system a little low on r22. Adjusted the superheated from 31 to 14degrees. 64 degrees coming from the supply vent. Vacuumed the drain system. No charge. Customer is having a new system installed on 9/30/2020


Marc M.

Marc M. Job Checkin

16 SEER 10 year parts and 1 year labor warranty proposal includes surge Suppressor at the condensing unit


Cliff P.

Cliff P. Job Checkin

Rewired thermostat and replaced weak run capacitor in outdoors Noticed that outdoor unit is R22 freon and indoor unit is designed to use 410a refrigerant. This is not the best match. Customer will call in payment


Cliff P.

Cliff P. Job Checkin

Rewired thermostat and replaced weak run capacitor in outdoors Noticed that outdoor unit is R22 freon and indoor unit is designed to use 410a refrigerant. This is not the best match. Customer will call in payment


Jeff M.

Jeff M. Job Checkin

AC SERVICE REPAIR ON A 4 TON CARRIER HEAT PUMP SYSTEM. INSTALLED NEW FLOAT SWITCH


Jeff M.

Jeff M. Job Checkin

AC SERVICE REPAIR ON A 3 TON LENNOX HEAT PUMP SYSTEM. REPLACED DEFROST BOARD


Jeff M.

Jeff M. Job Checkin

AC SERVICE REPAIR ON A 3 TON GOODMAN STRAIGHT COOL PACKAGE UNIT. REPAIRED BLOWER MOTOR.


Jeff M.

Jeff M. Job Checkin

AC SERVICE REPAIR ON A 3 TON LENNOX HEAT PUMP SYSTEM. ORDERED DEFROST BOARD.