8021 W. Gulf to Lake Hwy
Crystal River , FL 34429
352 795 2665

Local Reviews
for yankeetown, fl

Rated 4.9 out of 5 stars based on 52 customer reviews

Awesome service

Never felt with a better tech

  • Overall Experience
  • Quality
  • Price
  • Convenience

All good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

First encounter

I felt that Robert Hitsch was very knowledgeable and helpful with ideas. No salesman time speech , just direct and to the point information that I greatly appreciated. Good job !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Bay Area showed up as promised, was knowledgeable and attentive, accurate with diagnosis and had parts needed on the truck.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service. Very efficient.

No problems which was great !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and great price

Dale from Bay Area Air Conditioning responded quickly to my request for a service call late on Saturday afternoon. The AC at my Air B and B quit working when my Air B and B guest arrived. Dale was fast, courteous and professional. The entire result was excellent. Bay Area Air is now my go to place. I thank them greatly John Ritter

  • Overall Experience
  • Quality
  • Price
  • Convenience

Cliff did a great job

Bay air has handled our a/c repair needs several times and always do a great job at a fair price

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

These guys are great. They are professional, polite and respectful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for yankeetown, fl

Cliff P.

Cliff P. Job Checkin

Installed new thermostat, replaced failed re-settable fuse, ran system in heat and cool to ensure unit is running properly. System is running fine.


Cliff P.

Cliff P. Job Checkin

Installed new thermostat, replaced failed re-settable fuse, ran system in heat and cool to ensure unit is running properly. System is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Robert H.

Robert H. Job Checkin

Found water source unit for spare bedroom shutting off on overload and pressure switch was able to determine that discharge water valve was shut. Open water valve and unit is running normally at this time


Robert H.

Robert H. Job Checkin

Recorded measurements and window sizes for load calculation to quote Mini Split unit for main living area


Robert H.

Robert H. Job Checkin

Added one pound of r410a. Customer is aware that unit has leak. Let's pricing for new equipment


Cliff P.

Cliff P. Job Checkin

System had a failed relay as well as a weak capacitor not allowing the blower motor to run. Change both and unit is running and cooling fine.


Cliff P.

Cliff P. Job Checkin

System had a failed relay as well as a weak capacitor not allowing the blower motor to run. Change both and unit is running and cooling fine.


Cliff P.

Cliff P. Job Checkin

Condensing unit would not kick on due to a weak capacitor. Change capacitor air compressor is pulling 6.7 / 13.5 amps and the fan is pulling 1.2 / 1.4 amps. Unit is Cooling and running fine


Cliff P.

Cliff P. Job Checkin

Condensing unit would not kick on due to a weak capacitor. Change capacitor air compressor is pulling 6.7 / 13.5 amps and the fan is pulling 1.2 / 1.4 amps. Unit is Cooling and running fine


Cliff P.

Cliff P. Job Checkin

System has dirty evaporator coil, restricting dehumidification. Compressor amp draw is 8.9/18 and fan is .9/1.1. Filter was slightly dirty at time of arrival. P Trap was positioned in a way that it would allow air to be ducked in from outside and not dehumidify properly. Adjusted and printed p trap, cleaned coil, and instructed tenant to change filters more frequently. The mini split is operating fine. Pressures and temperature splits are normal and unit is cooling. If customer has issue with heat still, recommend adding fan to better circulate air, and possibly turn in exhaust fan in bathroom to remove warm air sitting near the ceiling.


Cliff P.

Cliff P. Job Checkin

System has dirty evaporator coil, restricting dehumidification. Compressor amp draw is 8.9/18 and fan is .9/1.1. Filter was slightly dirty at time of arrival. P Trap was positioned in a way that it would allow air to be ducked in from outside and not dehumidify properly. Adjusted and printed p trap, cleaned coil, and instructed tenant to change filters more frequently. The mini split is operating fine. Pressures and temperature splits are normal and unit is cooling. If customer has issue with heat still, recommend adding fan to better circulate air, and possibly turn in exhaust fan in bathroom to remove warm air sitting near the ceiling.