8021 W. Gulf to Lake Hwy
Crystal River , FL 34429
352 795 2665

Local Reviews
for yankeetown, fl

Rated 4.9 out of 5 stars based on 67 customer reviews

Fantastic!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Have been with Bay Area over 20 years. A super company!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Robert was very professional and told us a lot of imformation . Will let u know what we decide next week . Thank u the Murphy's

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Never felt with a better tech

  • Overall Experience
  • Quality
  • Price
  • Convenience

All good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

First encounter

I felt that Robert Hitsch was very knowledgeable and helpful with ideas. No salesman time speech , just direct and to the point information that I greatly appreciated. Good job !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Bay Area showed up as promised, was knowledgeable and attentive, accurate with diagnosis and had parts needed on the truck.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service. Very efficient.

No problems which was great !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and great price

Dale from Bay Area Air Conditioning responded quickly to my request for a service call late on Saturday afternoon. The AC at my Air B and B quit working when my Air B and B guest arrived. Dale was fast, courteous and professional. The entire result was excellent. Bay Area Air is now my go to place. I thank them greatly John Ritter

  • Overall Experience
  • Quality
  • Price
  • Convenience

Cliff did a great job

Bay air has handled our a/c repair needs several times and always do a great job at a fair price

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

These guys are great. They are professional, polite and respectful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

I think he was a good technician he I felt comfortable with them his experience to repair or to fix the AC I would definitely allow him to come back to do any of the AC repair

  • Overall Experience
  • Quality
  • Price
  • Convenience

worked hard to deal with Yankeetown building department.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for yankeetown, fl

Tyler H.

Tyler H. Job Checkin

Found system outdoor unit locked out. Power cycled unit and ran in heat mode. Suction pressure drops dramatically and never gets over 55psi, even with the outdoor txv sensing bulb in hand. Followed train troubleshooting guide for their great pumps which led me to verifying the charge before condemning the txv. Preformed leak search and found leaks in evaporator coil. Customer also told me that the unit struggled to cool towards the end of summer. Put in a part quote request form to verify whether or not the unit has a Part warranty. Charged the system with 4 lbs of refrigerant until the system pressures looked normal. Unit is heating fine.


Tyler H.

Tyler H. Job Checkin

Found air handler breaker tripped. Ran the unit in heat mode and checked heat strip amp draws, which are normal. Visually inspected all electrical components, ask if which were in good shape. Compared the required breaker size with the actual breaker size, they matched up. Checked the electrical connections for the high voltage in the air handler and in the breaker box. Found one leg of power's lug but to be very loose. This will cause overheating and tripped breakers. Tightened it up and unit is running fine.


Andrew C.

Andrew C. Job Checkin

Found outdoor unit was completely frozen. Attempted to force defrost mode and it would activate but only for a few seconds. Pulled the defrost thermostat off of board and jumped terminals. Tested defrost mode again and system would run defrost for an extended period of time. Defrost thermostat is not functioning properly, new part is needed to regain full functionality of system. Left system on emergency heat for the time being to prevent any further issues.


Cliff P.

Cliff P. Job Checkin

On arrival found that the thermostat was not properly mounted to the base. Took stat off wall and found that the wires were improperly connected to the base. Rewired the base and installed thermostat. Tested system operations and found no further issues. System is in good operating condition at this time.


Cliff P.

Cliff P. Job Checkin

System had a blown fuse at time of arrival. Isolated condensing unit and determined the short was there. Found two areas of rubbed out wires. Cut out the bad wire and spliced it together, checked the contactor and float switch to ensure neither were bad. Ran and tested unit which is running fine.


Cliff P.

Cliff P. Job Checkin

PERFORMED ANNUAL MAINTENANCE. System is operating normally at this time, flushed drain line and pan added Dawn detergent.


Robert H.

Robert H. Job Checkin

Best pricing for new equipment


Cliff P.

Cliff P. Job Checkin

Installed new thermostat, replaced failed re-settable fuse, ran system in heat and cool to ensure unit is running properly. System is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Robert H.

Robert H. Job Checkin

Found water source unit for spare bedroom shutting off on overload and pressure switch was able to determine that discharge water valve was shut. Open water valve and unit is running normally at this time


Robert H.

Robert H. Job Checkin

Recorded measurements and window sizes for load calculation to quote Mini Split unit for main living area


Robert H.

Robert H. Job Checkin

Added one pound of r410a. Customer is aware that unit has leak. Let's pricing for new equipment


Cliff P.

Cliff P. Job Checkin

System had a failed relay as well as a weak capacitor not allowing the blower motor to run. Change both and unit is running and cooling fine.


Cliff P.

Cliff P. Job Checkin

Condensing unit would not kick on due to a weak capacitor. Change capacitor air compressor is pulling 6.7 / 13.5 amps and the fan is pulling 1.2 / 1.4 amps. Unit is Cooling and running fine