JJ and his partner were amazing. They were extremely knowledgeable and completely transparent in everything they talked about and showed me. You can tell JJ takes a lot of pride in what he does. My AC/Furnace was installed in a very timely manner and couldn't look any better or more professionally done. I would highly recommend Bay and especially JJ!
I called on Monday morning and they were able to come over that day!
..it took three phones calls but problems solved at last. Justan knew the answer First phone call: no juice going to the A/C unit (I know you don't believe that.just ask Brian Second call: A/c shuts off at 1 hr and temp shoots up to 78 NoA/c at all Third Call: repeat of above.
Brian discovered that the switch in the main fuse box was in the off position for the A/C. no wonder the new install didn't work. Before he left the lead installer assured me that they did a thorough test of both units andeveryting was a-ok like Hell it was. Better give him a check-list until l he learns the job
Brian was on time, courteous and thorough. He even taught me a new maintenance trick!
Jose ! Great tech , So nice to see The New tech (TJ ) working with Jose ! Great pair ! Thanks Bay
Unit Smoking. Found A Bad 2-Shaft 1/3Hp Blower Motor, Need Replace.
No fan . I found a failed blower motor. I gave a quote for motor replacement and the customer will call back to reschedule.
No Cooling. 2= R-22 Unit. Goodman Unit Found A Plug Washable Filter Customers Washout And Bad Schrader Valve. Carrier Unit Found Low On Charge Add 2lb Of R-22 Recommed Super Seal Or Replace Unit. Candle wood suites would like a follow up for drain pump .
Maintenance agreement tune up is complete.
No Cooling. Found A Bad Circuit, Replace Circuit Cycled Unit Fine At This Time.
Found compressor valves going bad suction line pressure very high and discharge pressure fluctuating between 220 and 300 unit extremely old and must be replaced is cooling to only approximately 1/3 of its capacity
Unit Making Noise. Found Vine Going Into The Condenser Unit Remove A Plug #401Sg & Bad 40+440 Run Cap, Replace Both Cycled Unit Fine At This Time,
Customer said unit is working and will not shut off from the thermostat. Cycle unit on and off. Found that the contactor have welded. Replace contractor and cycle unit on and off for thermostat. At times of dispatch unit is working.
Found air conditioner working properly customer concerned with length of time it takes to pull down I told him approximately 1 to 2° per hour is the maximum for weather that we have been experiencing mid to upper 80s did find condensate trap plugged, cleared. Yelp free diagnostic.
No Cooling. Replace #201Sg Suppled. Found A/C R410A Low On Charge. Add 2lb Of R410A And Leak Seal, 74*-50*-14* D-T, 8* Subcooling, Cycled Unit Fine At This Time.
Went to estimate and neighbor used to work at hvac company and fixed A/C but wants replacement in Spring.
Club A/C Tuneup. Replace Bad 28+4.3+370 @ 35+5+370 Dual Run Cap, T-Stat, 72*-52*=20* D-T, Drain Trap, Blower Motor, R-22, Disconnect, 2=30 Amps Fuse, Electrical, 71* Outside, Hose Down, Remove Leaves And Cottonwood, Cycled Unit, Clean And Check.
No cooling. I found the reason was that each condenser is only receiving 120 volts. I found that the electrical panel has issues. I recommend calling an electrician to check the panel.
Check blower motor and filter clear condensate trap check contactor capacitor compressor and fan cycle air conditioner to check OK cleaned condenser coil